MULTIPORT FUEL INJECTION (MFI) DIAGNOSIS
TSB Revision
MULTIPORT FUEL INJECTION (MFI) <3.0L>
13B-537
STEP 1. Using scan tool MB991502, check data list item 16:
Power Supply Voltage.
CAUTION
To prevent damage to scan tool MB991502, always turn the
ignition switch to the "LOCK" (OFF) position before. con-
necting or disconnecting scan tool MB991502.
(1) Connect scan tool MB991502 to the data link connector.
(2) Turn the ignition switch to the "ON" position.
(3) Set scan tool MB991502 to the data reading mode for item
16, Power Supply Voltage.
•
Voltage should be battery positive voltage.
(4) Turn the ignition switch to the "LOCK" (OFF) position.
Q: Is the voltage normal?
YES :
Go to Step 2.
NO :
Refer to INSPECTION PROCEDURE 29
−
Power
Supply System and Ignition Switch
−
IG System
STEP 2. Check the burned-out bulb.
Q: Is the valve normal?
YES :
Go to step 3.
NO :
Replace the bulb. Then confirm that the malfunction
symptom is eliminated.
STEP 3. Check connector C-41 at the combination meter
for damage.
Q: Is the connector in good condition?
YES :
Go to step 4.
NO :
Repair or replace it. Refer to GROUP 00E, Harness
Connector Inspection
. Then confirm that the
malfunction symptom is eliminated.
AKX01177
16 PIN
MB991502
AB
AK000312AI
CONNECTOR:C-41