MULTIPORT FUEL INJECTION (MFI) DIAGNOSIS
TSB Revision
MULTIPORT FUEL INJECTION (MFI) <3.0L>
13B-368
.
CIRCUIT OPERATION
•
Power to the evaporative emission purge sole-
noid power is supplied from the MFI relay (termi-
nal 4).
•
The ECM <M/T> or PCM <A/T> controls ground
evaporative emission purge solenoid by turning
the power transistor in the ECM <M/T> or PCM
<A/T> "ON" and "OFF".
.
TECHNICAL DESCRIPTION
•
To judge if there is open circuit in the evaporative
emission purge solenoid drive circuit, ECM <M/
T> or PCM <A/T> measures the surge voltage of
the evaporative emission purge solenoid coil.
•
The ECM <M/T> or PCM <A/T> drives the evapo-
rative emission purge solenoid. After the solenoid
is turned off, the ECM <M/T> or PCM <A/T> will
check if the solenoid coil produces a surge volt-
age of 2 V or more.
.
DTC SET CONDITIONS
Check Conditions
•
Engine is being cranked.
•
Battery positive voltage is at between 10 and 16
volts.
Judgment Criteria
•
The evaporative emission purge solenoid coil
surge voltage (battery positive v 2 volts)
is not detected for 0.2 second.
•
The ECM <M/T> or PCM <A/T> monitors for this
condition once during the drive cycle.
Check Conditions
•
Battery positive voltage is at between 10 and 16
volts.
•
ON duty cycle of the evaporative emission purge
solenoid is between 10 and 90 percent.
•
ON duty cycle of the EGR solenoid is 0 percent.
•
Evaporative emission ventilation solenoid is OFF.
•
More than 1 second has elapsed after the above
mentioned conditions have been met.
Judgment Criteria
•
The evaporative emission purge solenoid coil
surge voltage (battery positive v 2 volts)
is not detected for 1 second. When the evapora-
tive emission purge solenoid is turned OFF.
.
TROUBLESHOOTING HINTS (The most likely
causes for this code to be set are:)
•
Evaporative emission purge solenoid failed.
•
Open or shorted evaporative emission purge
solenoid circuit, or loose connector.
•
ECM failed. <M/T>
•
PCM failed. <A/T>
DIAGNOSIS
Required Special Tool:
•
MB991502: Scan Tool (MUT-II)
AK000225
CONNECTOR : C-51<M/T>, C-52<A/T>
C-52
C-51
PCM<A/T>
ECM<M/T>
AJ
AK101363AB
MFI RELAY
CONNECTOR: A-18X