MULTIPORT FUEL INJECTION (MFI) DIAGNOSIS
TSB Revision
MULTIPORT FUEL INJECTION (MFI) <3.0L>
13B-330
STEP 4. Check connector B-22 at camshaft position
sensor for damage.
Q: Is the connector in good condition?
YES :
Go to Step 5.
NO :
Repair or replace it. Refer to GROUP 00E, Harness
Connector Inspection
. Then go to Step 20.
STEP 5. Check the sensor supply voltage at camshaft
position sensor connector B-22.
(1) Disconnect the connector B-22 and measure at the harness
side.
(2) Turn the ignition switch to the "ON" position.
(3) Measure the voltage between terminal 5 and ground.
•
Voltage should be between 4.8 and 5.2 volts.
(4) Turn the ignition switch to the "LOCK" (OFF) position.
Q: Is the voltage normal?
YES :
Go to Step 10.
NO :
Go to Step 6.
AK000217AB
AK000217
CONNECTOR: B-22
AK000250AB
B-22 HARNESS
SIDE CONNECTOR
7 6 5 4 3 2 1