MULTIPORT FUEL INJECTION (MFI) DIAGNOSIS
TSB Revision
MULTIPORT FUEL INJECTION (MFI) <3.0L>
13B-127
STEP 6. Check connector B-27 at right bank heated
oxygen sensor (front) and connector C-62 at ECM <M/T> or
connector C-59 at PCM <A/T> for damage.
Q: Is the connector in good condition?
YES :
Repair harness wire between right bank heated
oxygen sensor (front) connector B-27 terminal 4 and
ECM connector C-62 terminal 72 <M/T> or PCM
connector C-59 terminal 72 <A/T> because of open
circuit or harness damage. Then go to Step 15.
NO :
Repair or replace it. Refer to GROUP 00E, Harness
Connector Inspection
. Then go to Step 15.
STEP 7. Check connector B-27 at right bank heated
oxygen sensor (front) for damage.
Q: Is the connector in good condition?
YES :
Go to Step 8.
NO :
Repair or replace it. Refer to GROUP 00E, Harness
Connector Inspection
. Then go to Step 15.