MULTIPORT FUEL INJECTION (MFI) DIAGNOSIS
TSB Revision
MULTIPORT FUEL INJECTION (MFI) <3.0L>
13B-606
STEP 3. Check for open circuit and short circuit to ground
and harness damage between fan controller A-30 terminal
2 and ECM connector C-51 terminal 18 <M/T> or PCM
connector C-52 terminal 18 <A/T>.
NOTE: Check harness after checking intermediate connector
C-07. If intermediate connector is damaged, repair or replace
them. Refer to GROUP 00E, Harness Connector Inspection
. Then confirm that the malfunction symptom is elimi-
nated.
Q: Is the harness wire in good condition?
YES :
Refer to GROUP 14
−
Engine Cooling Diagnosis
−
NO :
Repair it. Then confirm that the malfunction symptom
is eliminated.
ACX02501 AE
CONNECTOR : A-30
FAN
CONTROLLER
AK000225
CONNECTOR : C-51<M/T>, C-52<A/T>
C-52
C-51
PCM<A/T>
ECM<M/T>
AJ