440
PARAMETER
(5) Command source selection for the Network operation mode [
Pr. 338, Pr. 339
]
As command sources, there are operation command
sources that control signals related to the inverter
start command and function selection and speed
command source that controls signals related to
frequency setting.
In the Network operation mode, the commands from
the external terminals and communication (RS-485
terminals or communication option) are as listed
below.
[
Pr. 338
] [
Pr. 339
] settings can be changed while
inverter is running when [
Pr. 77 =
2], but new setting
is reflected after a stop. Operation communication
command source and communication speed
command source, which are previously set, are kept
until a stop.
Operation
Location
Selection
[Pr. 338 Communication operation
command source]
0: NET
1: External
Remarks
[Pr. 339 Communication speed command
source]
0: NET
1:
External
2:
External 0: NET
1:
External
2:
External
Fixed function
(terminal-
equivalent
function)
Running frequency from communication
NET
—
NET
NET
—
NET
Terminal 2
—
External
—
—
External
—
Terminal 4
—
External
—
External
Terminal 1
Compensation
S
e
lec
tiv
e f
u
nc
tion
[
Pr
. 1
78
to
P
r.
18
9
]
se
tt
in
g
0
RL
Low speed operation command/remote
setting clear/stop-on contact selection 0
NET
External
NET
External
[
Pr. 59 = 0
]
(multi-speed)
[
Pr. 59
≠
0
]
(remote)
[
Pr. 270 = 1, 3
]
(stop-on-contact)
*1*3
1
RM
Middle speed operation command/
remote set deceleration
NET
External
NET
External
2
RH
High speed operation command/
remote set acceleration
NET
External
NET
External
3
RT
Second function selection/stop-on
contact selection 1
NET
External
[
Pr. 270 = 1, 3
]
(stop-on-contact)
*1*3
4
AU
Current input selection
—
Combined
—
Combined
5
JOG Jog operation selection
—
External
6
*2
CS
Selection of automatic restart after
instantaneous power failure
External
7
OH
External thermal relay input
External
8
REX Fifteen speed selection
NET
External
NET
External
[
Pr. 59 = 0
]
(multi-speed)
9
*1*2
X9
Third function selection
NET
External
10
X10 Inverter operation enable signal
External
11
*2
X11 FR-HC connection, instantaneous
power failure detection
External
12
X12 PU operation external interlock
External
13
*1*2
X13 External DC injection brake operation
start
NET
External
14
X14 PID control valid terminal
NET
External
NET
External
15
*1*3
BRI Brake opening completion signal
NET
External
16
X16 PU-external operation switchover
External
17
*1*2
X17 Load pattern selection forward rotation
reverse rotation boost
NET
External
18
*1
X18 V/F switching
NET
External
19
*1*2
X19 Load torque high-speed frequency
NET
External
20
*1*2
X20 S-pattern acceleration/deceleration C
switchover
NET
External
22
*1*2
X22 Orientation command
NET
External
23
*1*2
LX
Pre-excitation
NET
External
24
MRS
Output stop
Combined
External
[
Pr. 79
≠
7
]
PU operation interlock
External
[
Pr. 79 = 7
]
When the X12 signal is
not assigned
25
*1
STOP Start self-holding selection
—
External
26
*1*2
MC
Control mode switchover
NET
External
27
*1*2
TL
Torque limit selection
NET
External
28
*1*2
X28 Start-time tuning start external input
NET
External
42
*1*2
X42 Torque bias selection 1
NET
External
43
*1*2
X43 Torque bias selection 2
NET
External
44
*1*2
X44 P/PI control switchover
NET
External
60
STF Forward rotation command
NET
External
61
STR Reverse rotation command
NET
External
62
RES Reset
External
63
*2
PTC PTC thermistor selection
External
64
*2
X64 PID forward rotation action switchover
NET
External
NET
External
65
X65 PU-NET operation switchover
External
66
X66 NET-external operation switchover
External
67
X67 Command source switchover
External
68
*1
NP
Conditional position pulse train sign
External
69
*1*2
CLR Conditional position droop pulse clear
External
70
*1*2
X70 DC feeding operation permission
NET
External
71
*1*2
X71 DC feeding cancel
NET
External
74
*1*2
X74 Magnetic flux decay output shutoff
signal
NET
External