88
SPECIFICATIONS
(4) Encoder cable
When using the dedicated encoder cable (FR-JCBL, FR-
V5CBL, etc.) for the conventional motor, cut the crimpling
terminal of the encoder cable and strip its sheath to make
its cables loose.
Also, perform protective treatment of the shield to ensure
that it will not make contact with the conductive area.
Wire the stripped cable after twisting it to prevent it from
becoming loose. In addition, do not solder it.
Use a bar terminal as necessary.
Connection terminal compatibility table
SF-JR/HR/JRCA/HRCA with encoder
SF-V5RU, SF-THY
* As the terminal block of the FR-A7AP is an insertion type, cables need to be modified. (Refer to page 83)
L
F-DPEVSB 12P 0.2mm
2
MS3057-12A
Earth cable
MS3106B20-29S
60mm
Approx. 140mm
Model
Length L
(m)
FR-JCBL5
5
FR-JCBL15
15
FR-JCBL30
30
*
MS3106B20-29S
(As viewed from wiring side)
Positioning keyway
PZ2
PZ1
PB2
PB1
PA2
PA1
PG
SD
P
B
N
A
R
C
H
K
PLG
2mm
2
A
B
C
D
E
K
F
G
H
J
L
M
S
N
R
P
T
FR-A700
(FR-A7AP)
L
MS3106B20-29S
Earth cable
F-DPEVSB 12P 0.2mm
2
MS3057-12A
Encoder side
connector
Inverter side
60mm
11
m
m
Model
Length L
(m)
FR-V7CBL5
5
FR-V7CBL15
15
FR-V7CBL30
30
• P clip for earthing
(grounding) a shielded cable
is provided.
MS3106B20-29S
(As viewed from wiring side)
Positioning keyway
PZ2
PZ1
PA1
PB1
PB2
PA2
SD
PG
G
F
D
C
B
A
R
S
PLG
2mm
2
FR-A700
(FR-A7AP)
A
B
C
D
E
K
F
G
H
J
L
M
S
N
R
P
T
Cable stripping length
5mm
Motor
SF-V5RU
SF-THY
SF-JR/HR/
JRCA/HRCA
(with encoder)
Encoder cable
FR-V7CBL
FR-JCBL
FR-A7AP
terminal
PA1
PA
PA
PA2
Keep this open
PAR
PB1
PB
PB
PB2
Keep this open
PBR
PZ1
PZ
PZ
PZ2
Keep this open
PZR
PG
PG
5E
SD
SD
AG2