386
PARAMETER
2.18.4 Extended parameter display and user group function [Pr. 160, 172 to 174*]
(common)
Parameter which can be read from the operation panel and parameter unit can be restricted.
(1) Display of simple mode parameters and
extended parameters [Pr. 160]
When [
Pr. 160
= 9999], only the simple mode
parameters can be displayed on the control panel (FR-
DU07) and parameter unit (FR-PU04/FR-PU-07). (Refer
to the parameter list on page 120, for the simple mode
parameters.)
When [
Pr. 160
= 0], simple mode parameters and
extended parameters can be displayed.
All parameter can be read regardless of [Pr.160]
setting when performing parameter read using a
communication option in
.
When reading parameters with RS-484
communication made by RS-485 terminal in
or PU connector in
, all
parameters can be read regardless of [
Pr. 160
] setting
by setting [
Pr. 550 NET mode operation command source
selection
] and [
Pr. 551 PU mode operation command source
selection
] as the below table.
*1
Indicates initial value.
*2
OP indicates a communication option.
*3
Parameter read cannot be performed when read is
restricted by the [
Pr. 296 Password lock level
] setting under
the NET mode. (Refer to page 387)
[
Pr. 15 Jog frequency
], [
Pr. 16 Jog acceleration/
deceleration time
], and [
Pr. 991 PU contrast adjustment
]
are displayed as simple mode parameter when the
parameter unit (FR-PU04/FR-PU07) is fitted.
(2) User group function [Pr. 160, 172 to
174]
The user group function is designed to display only
the parameters necessary for the setting.
Among all parameters, a maximum of 16 parameters
can be registered to the user group. When [
Pr. 160
=
1], only parameters registered in the user group can
be accessed for reading and writing. (The
common
(*[Pr. 172 to 174] are not available for
.)
[Pr. ]
Name
Initial Value
Setting Range
Description
Available Inverters
160
User group read selection
Extended function display
selection
0
9999
9999
Only the simple mode
parameters can be
displayed.
{
{
0
The simple mode and
extended parameters can
be displayed
1
Only the parameters
registered to the user group
can be displayed.
—
172
User group registered
display/batch clear
0
(0 to 16)
Displays the number of
parameters registered as a
user group (Reading only)
{
—
9999
Batch clear the user group
registration
173
*1
User group registration
9999
0 to 999, 9999
Set the parameter numbers to
be registered to the user
group.
{
—
174
*1
User group clear
9999
0 to 999, 9999
Set the parameter numbers to
be cleared from the user
group.
{
—
*1
The values read from [
Pr. 173, Pr. 174
]
are always 9999.
D700
A700
F700
E700
D700
A700 F700 E700
D700
A700 E700
F700 D700
Inverters
[Pr. 551]
[Pr. 550]
OP
*2
2(PU)
*1
3(USB)
1
—
9999
(auto detect)
*1
Invalid
2(PU)
*1
1
—
9999(auto
detect)
*1
Invalid
A700
F700
E700
A700
F700
E700
D700
A700
F700
3(USB)
9999
(auto detect)
*1
2(PU)
—
9999(auto
detect)
*1
Invalid
*3
4(operation
panel)
9999(auto
detect)
*1
—
—
Inverters
[Pr. 551]
[Pr. 550]
OP
*2
E700
D700
A700
F700
E700
Содержание FR-A700 Series
Страница 245: ...279 2 PARAMETER PARAMETER MEMO ...
Страница 440: ...474 PARAMETER MEMO ...
Страница 522: ...556 SELECTION MEMO ...