PARAMETER
(2) Pulse train form selection (PP, NP signal) [Pr. 428]
Command pulse can be changed according to the
positioning unit as in the table below.
(3) Interface of the positioning unit and inverter
When running the inverter by each positioning unit,
interface of the positioning command pulse train
need to be matched.
Command Pulse Train Form
At Forward
Rotation
At Reverse
Rotation
Setting
[
Pr. 428
]
Remarks
Nega
tive logi
c
Forward rotation pulse train
Reverse rotation pulse train
0
(factory
setting)
QD75D(CW/CWW mode)
(Note) If (CW/CWW mode) and (PLS/
SIGN mode) are mistaken, the motor
runs only in one direction.
Pulse train + rotation direction sign
1
QD75D (PLS/SIGN mode)
A phase pulse train
B phase pulse train
2
Counted after multiplying by four.
Set the pulse train frequency multiplied
by four to 500kpps or less with the
differential driver type and to 200kpps or
less with the open collector type.
Pos
itive
log
ic
Forward rotation pulse train
Reverse rotation pulse train
3
Pulse train + rotation direction sign
4
A phase pulse train
B phase pulse train
5
Counted after being multiplied by four.
Set the pulse train frequency multiplied
by four to 500kpps or less with the
differential driver type and to 200kpps or
less with the open collector type.
PP
NP
PP
NP
H
L
PP
NP
PP
NP
PP
NP
H
L
PP
NP
Output Type
Hardware Configuration
Input Pulse Frequency
Open collector
Max. 200kpps
Differential line driver
Max. 500kpps
PP(NP)
OPC
VDD
Command unit
Inverter (FR-A7AL)
*: Wiring length : max. 2m
+24
SD
Connect
externally
(PGN)
PGP
PP(NP)
OPC
VDD
+24
Command unit
*: Wiring length : max. 10m
Inverter (FR-A7AL)
Do not
connect