SPECIFICATIONS
Cont
act
input
STF
*1
Forward
rotation start
input signal
terminal
Input resistance : 4.7k
Voltage when contacts are open :
21 to 27VDC
21 to 26VDC
When contacts are short-
circuited : 4 to 6mADC
Isolated by photocoupler
Controls by open collector
output or no voltage contact
signal.
Turning ON STF signal gives forward
command and off gives stop
command.
Turning ON STR signal gives reverse
command and off gives stop
command.
Turning ON STF and STR signals
simultaneously gives stop command.
{
{
{
{
STR
*1
Reverse
rotation start
input signal
terminal
{
{
{
{
STOP
*1
Start self-
holding
selection
terminal
Input resistance : 4.7k
Voltage when contacts are open :
21 to 27VDC
When contacts are short-
circuited : 4 to 6mADC
Isolated by photocoupler
Controls by open collector
output or no voltage contact
signal.
Turning ON STOP signal selects the
self-hodling start method.
If the start signal STF (STR) is once
turned ON, the start signal is held
and the inverter continues running.
To stop the motor, turn OFF terminal
STOP. To change the rotation
direction, turn ON, then OFF the start
signal STR (STF).
The self-holding start method
prevents the inverter from
automatically restarting when power
is restored after a power failure.
{
{
—
—
RH, RM,
RL
*1
Three
speeds
selection
Input resistance : 4.7k
Voltage when contacts are open :
21 to 27VDC
21 to 26VDC
When contacts are short-
circuited : 4 to 6mADC
Isolated by photocoupler
Controls by open collector
output or no voltage contact
signal.
Turn ON RH signal to perform
operation at the frequency set in [
Pr.
4
]. Turn ON RM signal to perform
operation at the frequency set in [
Pr.
5
] or turn ON RL signal to perform
operation at the frequency set in [
Pr.
6
].
When any two or more terminals of
RH, RM and RL are turned ON at the
same time, priority is given to the
lower-speed signal. Three speeds
selection has higher priority than the
analog frequency setting signal.
{
{
{
{
Multi-speed
selection
terminal
For multi-speed selection, setting
multi-speed frequencies in [
Pr. 24 to
Pr. 27, Pr. 232 to Pr. 239
] allows up to
15 speeds to be selected by the
combinations of RH, RM, RL, REX
signal. Allocate REX signal to any of
the terminals using input terminal
function selection.
Multi-speed selection has higher
priority than the analog frequency
setting signal.
{
{
{
{
JOG
*1
Jog mode
selection
terminal
Input resistance 4.7k
Voltage when contacts are open :
21 to 27VDC
When contacts are short-
circuited : 4 to 6mADC
Isolated by photocoupler
Controls by open collector
output or no voltage contact
signal
Turn ON JOG signal and use terminal
STF (STR) signal to run/stop.
{
{
—
—
Pulse train
input
terminal
Input resistance : 2k
When contacts are short-
circuited : 8 to 13 mADC
Maximum input pulse :
100kpulse/s
Isolated by photocoupler
Controllable by open collector
output or complementary
output (power supply voltage
24V)
JOG terminal can be used as pulse
train input terminal.
To use as pulse train input terminal,
the [
Pr. 291
] setting needs to be
changed.
{
—
—
—
RT
*1
Second
function
selection
terminal
Input resistance 4.7k
Voltage when contacts are open :
21 to 27VDC
When contacts are short-
circuited : 4 to 6mADC
Isolated by photocoupler
Controls by open collector
output or no voltage contact
signal
When second function such as [
Pr.
44, Pr. 45, Pr. 46
] is set, turning ON RT
signal selects the second function.
{
{
—
—
Ty
p
e Terminal
Symbol
Terminal
Name
Rating, etc.
Application Explanation
Available Inverters
Refer
to
Page
A700
F700
E700
D700
A700
F700
E700
D700
A700
F700
E700
D700