204
PARAMETER
Operation selection
at power failure and
instantaneous power
failure
Automatic restart operation after
instantaneous power failure/flying start
[
Pr. 57
], [
Pr. 58
], [
Pr. 162 to Pr. 165
],
[
Pr. 299
], [
Pr. 611
]
[
Pr. 57
], [
Pr. 58
], [
Pr. 162 to Pr. 165
],
[
Pr. 299
], [
Pr. 611
]
When undervoltage or a power failure
occurs, the inverter can be decelerated
to a stop
[
Pr. 261 to Pr. 266
], [
Pr. 294
]
[
Pr. 261 to Pr. 266
]
Operation setting at
fault occurrence
Retry function at fault occurrence
[
Pr. 65
], [
Pr. 67 to Pr. 69
]
[
Pr. 65
], [
Pr. 67 to Pr. 69
]
Output function of fault code
[
Pr. 76
]
[
Pr. 76
]
Input/output phase loss protection
selection
[
Pr. 251
], [
Pr. 872
]
[
Pr. 251
], [
Pr. 872
]
Fault definition
[
Pr. 875
]
—
Regeneration avoidance function
[
Pr. 882 to Pr. 886
]
[
Pr. 882 to Pr. 886
]
Energy saving
operation
Energy saving control selection
(optimum excitation control)
[
Pr. 60
]
[
Pr. 60
]
How much energy can be saved
(energy saving monitor)
[
Pr. 891 to Pr. 899
]
[
Pr. 891 to Pr. 899
]
Reduction of the
motor noise
Measures against
EMI and leakage
currents
Carrier frequency and Soft-PWM
selection
[
Pr. 72
], [
Pr. 240
]
[
Pr. 72
], [
Pr. 240
], [
Pr. 260
]
Noise elimination at the analog input
[
Pr. 74
], [
Pr. 822
], [
Pr. 826
], [
Pr. 832
],
[
Pr. 836
], [
Pr. 849
]
[
Pr. 74
]
Frequency setting by
analog input
Analog input selection
[
Pr. 73
], [
Pr. 267
]
[
Pr. 73
], [
Pr. 267
]
Override function
[
Pr. 73
], [
Pr. 252
], [
Pr. 253
]
[
Pr. 73
], [
Pr. 252
], [
Pr. 253
]
Noise elimination at the analog input
[
Pr. 74
], [
Pr. 822
], [
Pr. 826
], [
Pr. 832
],
[
Pr. 836
], [
Pr. 849
]
[
Pr. 74
]
Change of analog input frequency,
Adjustment of voltage, current input and
frequency (calibration)
[
Pr. 125
], [
Pr. 126
], [
Pr. 241
], [
C2 to
C7
] ([
Pr. 902 to Pr. 905
])
[
Pr. 125
], [
Pr. 126
], [
Pr. 241
], [
C2 to
C7
] ([
Pr. 902 to 905
])
Analog input compensation
[
Pr. 242
], [
Pr. 243
]
[
Pr. 242
], [
Pr. 243
]
Misoperation
prevention and
parameter setting
restriction
Reset selection, disconnected PU
detection
[
Pr. 75
]
[
Pr. 75
]
Prevention of parameter rewrite
[
Pr. 77
]
[
Pr. 77
]
Prevention of reverse rotation of the
motor
[
Pr. 78
]
[
Pr. 78
]
Display necessary parameters only
(user group)
[
Pr. 160
], [
Pr. 172 to 174
]
[
Pr. 160
], [
Pr. 172 to 174
]
Control of parameter write by
communication
[
Pr. 342
]
[
Pr. 342
]
Selection of
operation mode and
operation location
Operation mode selection
[
Pr. 79
]
[
Pr. 79
]
Operation mode when power is ON
[
Pr. 79
], [
Pr. 340
]
[
Pr. 79
], [
Pr. 340
]
Operation command source and speed
command source during
communication operation
[
Pr. 338
], [
Pr. 339
]
[
Pr. 338
], [
Pr. 339
]
NET mode command source selection
[
Pr. 550
]
[
Pr. 550
]
PU mode command source selection
[
Pr. 551
]
[
Pr. 551
]
Purpose of Use
Parameter Number
FR-A700
FR-F700