132
PA
R
A
M
E
T
E
R
2
132
PARAMETER
PARAMETER
16
bit
s
digit
a
l input
300
BCD input bias
0 to 400Hz
0.01Hz
0Hz
300
00
80
3
{
{
{
{
×
{
{
{
{
{
301
BCD input gain
0 to 400Hz, 9999
0.01Hz
60Hz
301
01
81
3
{
{
{
{
×
{
{
{
{
{
302
BIN input bias
0 to 400Hz
0.01Hz
0Hz
302
02
82
3
{
{
{
{
×
{
{
{
{
{
303
BIN input gain
0 to 400Hz, 9999
0.01Hz
60Hz
303
03
83
3
{
{
{
{
×
{
{
{
{
{
304
Digital input and analog input compensation
enable/disable selection
0 to 4, 10 to 14, 9999
1
9999
304
04
84
3
{
{
{
{
×
{
{
{
{
{
305
Read timing operation selection
0, 1, 10
1
0
305
05
85
3
{
{
{
{
×
{
{
{
{
{
Ext
ension analog
out
put
306
Analog output signal selection
1 to 3, 5 to 14, 17, 18, 21, 24,
32 to 34, 50, 52, 53
1
2
306
06
86
3
{
{
{
{
{
{
{
{
{
{
307
Setting for zero analog output
0 to 100%
0.1%
0%
307
07
87
3
{
{
{
{
{
{
{
{
{
{
308
Setting for maximum analog output
0 to 100%
0.1%
100%
308
08
88
3
{
{
{
{
{
{
{
{
{
{
309
Analog output signal voltage/current
switchover
0, 1, 10, 11
1
0
309
09
89
3
{
{
{
{
{
{
{
{
{
{
310
Analog meter voltage output selection
1 to 3, 5 to 14, 17, 18, 21, 24,
32 to 34, 50, 52, 53
1
2
310
0A
8A
3
{
{
{
{
{
{
{
{
{
{
311
Setting for zero analog meter voltage
output
0 to 100%
0.1%
0%
311
0B
8B
3
{
{
{
{
{
{
{
{
{
{
312
Setting for maximum analog meter voltage
output
0 to 100%
0.1%
100%
312
0C
8C
3
{
{
{
{
{
{
{
{
{
{
Digit
al
out
put
313
DO0 output selection
0 to 8, 10 to 20, 25 to 28, 30
to 36, 39, 41 to 47, 64, 70, 84
to 99, 100 to 108, 110 to 116,
120, 125 to 128, 130 to 136,
139, 141 to 147, 164, 170,
184 to 199, 9999
1
9999
313
0D
8D
3
{
{
{
{
{
{
{
{
{
{
314
DO1 output selection
1
9999
314
0E
8E
3
{
{
{
{
{
{
{
{
{
{
315
DO2 output selection
1
9999
315
0F
8F
3
{
{
{
{
{
{
{
{
{
{
316
DO3 output selection
1
9999
316
10
90
3
{
{
{
{
{
{
{
{
{
{
317
DO4 output selection
1
9999
317
11
91
3
{
{
{
{
{
{
{
{
{
{
318
DO5 output selection
1
9999
318
12
92
3
{
{
{
{
{
{
{
{
{
{
319
DO6 output selection
1
9999
319
13
93
3
{
{
{
{
{
{
{
{
{
{
Relay
out
put
320
RA1 output selection
0 to 8, 10 to 20, 25 to 28, 30
to 36, 39, 41 to 47, 64, 70, 84
to 91, 94 to 99, 9999
1
0
320
14
94
3
{
{
{
{
{
{
{
{
{
{
321
RA2 output selection
1
1
321
15
95
3
{
{
{
{
{
{
{
{
{
{
322
RA3 output selection
1
2
322
16
96
3
{
{
{
{
{
{
{
{
{
{
Calibration
323
AM0 0V adjustment
900 to 1100%
1
1000%
323
17
97
3
{
{
{
{
{
{
{
{
×
{
324
AM1 0mA adjustment
900 to 1100%
1
1000%
324
18
98
3
{
{
{
{
{
{
{
{
×
{
—
329
Digital input unit selection
0, 1, 2, 3
1
1
329
1D
9D
3
{
{
{
{
×
{
{
{
×
{
RS
-485 com
m
unicat
ion
331
RS-485 communication station number
0 to 31 (0 to 247)
1
0
331
1F
9F
3
{
{
{
{
{
{
{
{
{
{
332
RS-485 communication speed
3, 6, 12, 24, 48, 96, 192, 384
1
96
332
20
A0
3
{
{
{
{
{
{
{
{
{
{
333
RS-485 communication stop bit length
0, 1, 10, 11
1
1
333
21
A1
3
{
{
{
{
{
{
{
{
{
{
334
RS-485 communication parity check
selection
0, 1, 2
1
2
334
22
A2
3
{
{
{
{
{
{
{
{
{
{
335
RS-485 communication retry count
0 to 10, 9999
1
1
335
23
A3
3
{
{
{
{
{
{
{
{
{
{
336
RS-485 communication check time interval 0 to 999.8s, 9999
0.1s
0s
336
24
A4
3
{
{
{
{
{
{
{
{
{
{
337
RS-485 communication waiting time setting 0 to 150ms, 9999
1
9999
337
25
A5
3
{
{
{
{
{
{
{
{
{
{
338
Communication operation command source 0, 1
1
0
338
26
A6
3
{
{
{
{
{
{
{
{
{
{
339
Communication speed command source
0, 1, 2
1
0
339
27
A7
3
{
{
{
{
{
{
{
{
{
{
340
Communication startup mode selection
0, 1, 2, 10, 12
1
0
340
28
A8
3
{
{
{
{
{
{
{
{
{
{
341
RS-485 communication CR/LF selection
0, 1, 2
1
1
341
29
A9
3
{
{
{
{
{
{
{
{
{
{
342
Communication EEPROM write selection
0, 1
1
0
342
2A
AA
3
{
{
{
{
{
{
{
{
{
{
343
Communication error count
—
1
0
343
2B
AB
3
{
{
{
{
{
{
{
×
×
×
D
e
vi
ce N
e
t
com
m
unicat
ion
345
DeviceNet address
0 to 4095
1
63
—
345
2D
AD
3
{
{
{
{
{
{
{
{
{
{
346
DeviceNet baud rate
0 to 4095
1
132
—
346
2E
AE
3
{
{
{
{
{
{
{
{
{
{
Com
m
uni
ca
tion
349
Communication reset selection
0, 1
1
0
—
349
31
B1
3
{
{
{
{
{
{
{
{
{
{
Fu
nct
io
n
[Pr.]
Name
Setting Range
Minimum Setting
Increments
Initial Value
Refer to
Page
[Pr.]
Option
Instruction Code
Control Mode-based Correspondence Table
P
ar
a
me
te
r
Cop
y
P
ar
a
me
te
r
Cle
a
r
All P
ara
me
te
r
Cle
a
r
Re
ad
Wr
it
e
E
xt
ende
d
V/F
con
tr
o
l
Advanced
magnetic
flux
vector
control
Vector control
Real sensorless
vector control
S
p
eed
co
nt
ro
l
To
rque
co
nt
ro
l
Po
sit
ion
co
nt
ro
l
Speed
control
Torque
control
Содержание FR-A700 Series
Страница 245: ...279 2 PARAMETER PARAMETER MEMO ...
Страница 440: ...474 PARAMETER MEMO ...
Страница 522: ...556 SELECTION MEMO ...