206
PARAMETER
2.2.2
FR-E700, D700
Set parameters according to the operating conditions. The following list indicates purpose of use and corresponding
parameters.
Purpose of Use
Parameter Number
FR-E700
FR-D700
Control mode
Change the control method
[
Pr. 80
], [
Pr. 81
], [
Pr. 800
]
[
Pr. 80
]
Adjust the output
torque (current) of
the motor
Torque boost
[
Pr. 0
], [
Pr. 46
]
[
Pr. 0
], [
Pr. 46
]
Advanced magnetic flux vector control
[
Pr. 80
], [
Pr. 81
], [
Pr. 89
], [
Pr. 800
]
—
General-purpose magnetic-flux vector
control
[
Pr. 80
], [
Pr. 81
], [
Pr. 800
]
[
Pr. 80
]
Slip compensation
[
Pr. 245 to Pr. 247
]
[
Pr. 245 to Pr. 247
]
Stall prevention operation
[
Pr. 22
], [
Pr. 23
], [
Pr. 48
], [
Pr. 66
], [
Pr.
156
], [
Pr. 157
], [
Pr. 277
]
[
Pr. 22
], [
Pr. 23
], [
Pr. 48
], [
Pr. 66
], [
Pr.
156
], [
Pr. 157
]
Limit the output
frequency
Maximum/minimum frequency
[
Pr. 1
], [
Pr. 2
], [
Pr. 18
]
[
Pr. 1
], [
Pr. 2
], [
Pr. 18
]
Avoid mechanical resonance points
(frequency jump)
[
Pr. 31 to 36
]
[
Pr. 31 to 36
]
Set V/F pattern
Base frequency, voltage
[
Pr. 3
], [
Pr. 19
], [
Pr. 47
]
[
Pr. 3
], [
Pr. 19
], [
Pr. 47
]
V/F pattern matching applications
[
Pr. 14
]
[
Pr. 14
]
Frequency setting
with terminals
(contact input)
Multi-speed setting operation
[
Pr. 4
to Pr. 6
], [
Pr. 24 to Pr. 27
], [
Pr.
232 to Pr. 239
]
[
Pr. 4 to Pr. 6
], [
Pr. 24 to Pr. 27
], [
Pr.
232 to Pr. 239
]
Jog operation
[
Pr. 15
], [
Pr. 16
]
[
Pr. 15
], [
Pr. 16
]
Remote setting function
[
Pr. 59
]
[
Pr. 59
]
Acceleration/
deceleration time/
pattern adjustment
Acceleration/deceleration time
[
Pr. 7
], [
Pr. 8
], [
Pr. 20
], [
Pr. 21
], [
Pr.
44
], [
Pr. 45
], [
Pr. 147
]
[
Pr. 7
], [
Pr. 8
], [
Pr. 20
], [
Pr. 44
], [
Pr.
45
]
Starting frequency
[
Pr. 13
], [
Pr. 571
]
[
Pr. 13
], [
Pr. 571
]
Acceleration/deceleration pattern
[
Pr. 29
]
[
Pr. 29
]
Set a shortest and optimum acceleration/
deceleration time automatically
(automatic acceleration/deceleration)
[
Pr. 61 to Pr. 63
], [
Pr. 292
], [
Pr. 293
]
—
Regeneration avoidance function
[
Pr. 665
], [
Pr. 882
], [
Pr. 883
], [
Pr. 885
],
[
Pr. 886
]
[
Pr. 665
], [
Pr. 882
], [
Pr. 883
], [
Pr. 885
],
[
Pr. 886
]
Selection and
protection of a motor
Motor protection from overheat
(electronic thermal relay function )
[
Pr. 9
], [
Pr. 51
]
[
Pr. 9
], [
Pr. 51
]
Use the constant-torque motor
(applied motor)
[
Pr. 71
], [
Pr. 450
]
[
Pr. 71
], [
Pr. 450
]
Offline auto tuning
[
Pr. 71
], [
Pr. 82 to Pr. 84
], [
Pr. 90 to
94
], [
Pr. 96
], [
Pr. 859
]
[
Pr. 71
], [
Pr. 82 to Pr. 84
], [
Pr. 90
], [
Pr.
96
]
Motor brake and stop
operation
DC injection brake
[
Pr. 10 to Pr. 12
]
[
Pr. 10 to Pr. 12
]
Selection of regeneration unit
[
Pr. 30
], [
Pr. 70
]
[
Pr. 30
], [
Pr. 70
]
Selection of motor stopping method
and start signal
[
Pr. 250
]
[
Pr. 250
]
When undervoltage or a power failure
occurs, the inverter can be decelerated
to a stop.
[
Pr. 261
]
[
Pr. 261
]
Stop-on-contact control
[
Pr. 6
], [
Pr. 270
], [
Pr. 275
], [
Pr. 276
]
—
Brake sequence function
[
Pr. 278 to Pr. 283
], [
Pr. 292
]
—
Содержание FR-A700 Series
Страница 245: ...279 2 PARAMETER PARAMETER MEMO ...
Страница 440: ...474 PARAMETER MEMO ...
Страница 522: ...556 SELECTION MEMO ...