![Keysight Technologies N69100 Series Скачать руководство пользователя страница 49](http://html1.mh-extra.com/html/keysight-technologies/n69100-series/n69100-series_operating-and-service-manual_1962218049.webp)
N69143A, N69145A, and N69146A units
For the high current models, EDP does not limit the allowable programmable waveform amplitude or
frequency. You can program a full scale square wave at a maximum frequency of 97.6 kHz indefinitely.
Output Quadrants
Model
+ V1
+ V2
+ V3
+ I1
+ I2
- I2
P1
Sinking
resistance
N69143A
20 V
12.5 V
0.5 V
500 A
800 A
80 A
10 kW
625 µ
Ω
N69145A
80 V
40 V
0.75 V
125 A
250 A
25 A
10 kW
3 m
Ω
N69146A
160 V
80 V
1.5 V
62.5 A
125 A
12.5 A
10 kW
12 m
Ω
N69172A
1000 V
333 V
0.78 V
20 A
60 A
6 A
20 kW
130 m
Ω
N69173A
2000 V
666 V
1.5 V
10 A
30 A
3 A
20 kW
500 m
Ω
Keysight N69100 Series Operating and Service Guide
49
1 Quick Reference
Содержание N69100 Series
Страница 1: ...Keysight Advanced Power System DC Power Supply N69100 Series Operating and Service Guide...
Страница 2: ......
Страница 14: ......
Страница 50: ...Outline Diagram for 10 kW Models 1 Quick Reference 50 Keysight N69100 Series Operating and Service Guide...
Страница 51: ...Outline Diagram for 20 kW Models Keysight N69100 Series Operating and Service Guide 51 1 Quick Reference...
Страница 52: ......
Страница 80: ......
Страница 94: ......
Страница 210: ...Status Diagram 5 SCPI Programming Reference 210 Keysight N69100 Series Operating and Service Guide...
Страница 212: ...Trigger Diagram 5 SCPI Programming Reference 212 Keysight N69100 Series Operating and Service Guide...
Страница 230: ...Models N69172A and N69173A 6 Verification and Calibration 230 Keysight N69100 Series Operating and Service Guide...
Страница 244: ......