![Keysight Technologies N69100 Series Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/keysight-technologies/n69100-series/n69100-series_operating-and-service-manual_1962218033.webp)
Specifications and Characteristics
AC Input Efficiency, Power Factor, and THD
Inductive Load Boundary for Constant Current (CC) Operation
Capacitive Load Boundary for Constant Voltage (CV) Operation
Specifications
Unless otherwise noted, specifications are warranted over the ambient temperature range of 0 to
40°C after a 30-minute warm-up. Specifications apply at the output terminals, with local sensing.
Specification
N69143A
N69145A
N69146A
N69172A
N69173A
DC Ratings
Voltage source:
Current source and sink:
Power:
0 to 20 V
0 to 800 A; -80 A
10 kW
0 to 80 V
0 to 250 A; -25 A
10 kW
0 to 160 V
0 to 125 A; -12.5 A
10 kW
0 to 1000 V
0 to 60 A; -6 A
20 kW
0 to 2000 V
0 to 30 A; -3 A
20 kW
Output ripple & noise
CV peak-to-peak:1
CV rms:2
30 mV
3 mV
80 mV
8 mV
200 mV
20 mV
1.5 V
200 mV
3 V
400 mV
Load regulation
Voltage:3
Current:
1 mV
50 mA
3 mV
25 mA
6 mV
13 mA
50 mV
8 mA
100 mV
4 mA
Voltage programming &
measurement accuracy:4
0.02% + 4 mV
0.02% + 13 mV
0.02% + 26 mV
0.04% + 120 mV
0.04% + 240 mV
Current programming &
measurement accuracy:4
0.09% + 370 mA
0.06% + 115 mA
0.06% + 58 mA
0.09% + 23 mA
0.09% + 12 mA
Transient response5
Recovery Time:
Settling band:
900 µs
0.2 V
900 µs
0.8 V
900 µs
1.6 V
900 µs
10 V
900 µs
20 V
1 From 20 Hz to 20 MHz (-3dB bandwidth) with resistive load, terminals ungrounded, or either terminal grounded
2 From 20 Hz to 10 MHz (-3dB bandwidth) with resistive load, terminals ungrounded, or either terminal grounded
3 Also applies when remote sensing with a ≤1 V drop per load lead - see
and
for additional information.
4 Percent of value + offset; at 25°C ±5°C after a 30 minute warm-up; measurement NPLC=1; valid for 1 year, see
with a ≤1 V drop per load lead - see
for information about additional load lead voltage drop
5 Time to recover to within the settling band following a step change from 40% to 90% and 90% to 40% of full load at Comp 0, with a 40 μs
current rise and fall time
Keysight N69100 Series Operating and Service Guide
33
1 Quick Reference
Содержание N69100 Series
Страница 1: ...Keysight Advanced Power System DC Power Supply N69100 Series Operating and Service Guide...
Страница 2: ......
Страница 14: ......
Страница 50: ...Outline Diagram for 10 kW Models 1 Quick Reference 50 Keysight N69100 Series Operating and Service Guide...
Страница 51: ...Outline Diagram for 20 kW Models Keysight N69100 Series Operating and Service Guide 51 1 Quick Reference...
Страница 52: ......
Страница 80: ......
Страница 94: ......
Страница 210: ...Status Diagram 5 SCPI Programming Reference 210 Keysight N69100 Series Operating and Service Guide...
Страница 212: ...Trigger Diagram 5 SCPI Programming Reference 212 Keysight N69100 Series Operating and Service Guide...
Страница 230: ...Models N69172A and N69173A 6 Verification and Calibration 230 Keysight N69100 Series Operating and Service Guide...
Страница 244: ......