![Keysight Technologies N69100 Series Скачать руководство пользователя страница 178](http://html1.mh-extra.com/html/keysight-technologies/n69100-series/n69100-series_operating-and-service-manual_1962218178.webp)
LIST Subsystem
List commands program an output sequence of multiple voltage or current settings. A comma-
delimited list of up to 512 steps may be programmed. Note that these commands only apply in the
presently active priority mode, either voltage priority or current priority.
[SOURce:]LIST:COUNt <
value
>|MIN|MAX|INFinity
[SOURce:]LIST:COUNt? [MIN|MAX]
Sets the list repeat count. This sets the number of times that a list is executed before it completes. The
count range is 1 through 4096. Infinity runs the list continuously.
Parameter
Typical Return
1 – 4096, *RST 1
<count>
Sets the list count to 10: LIST:COUN 10
[SOURce:]LIST:CURRent[:LEVel] <
value
>{,<
value
>}
[SOURce:]LIST:CURRent[:LEVel]?
[SOURce:]LIST:VOLTage[:LEVel] <
value
>,{<
value
>}
[SOURce:]LIST:VOLTage[:LEVel]?
Specifies the setting for each list step. Values are specified in either amperes or volts.
Parameter
Typical Return
Voltage: 0 to 102% of rating
Current: -102% to 102% of rating
<list value 1>,<list value 2>,<list value 3>
Programs a current list. The list contains 3 steps:LIST:CURR 3,2,1
Programs a voltage list. The list contains 3 steps:LIST:VOLT 20,10,5
[SOURce:]LIST:DWELl <
value
>{,<
value
>}
[SOURce:]LIST:DWELl?
Specifies the dwell time for each list step. Dwell time is the time that the output will remain at a
specific step. Dwell times can be programmed from 0 through 262.144 seconds with the following
resolution:
Range in seconds
Resolution
0 - 0.262144
1 microsecond
0.262144 - 2.62144
10 microseconds
2.62144 - 26.2144
100 microseconds
26.2144 - 262.144
1 millisecond
5 SCPI Programming Reference
178
Keysight N69100 Series Operating and Service Guide
Содержание N69100 Series
Страница 1: ...Keysight Advanced Power System DC Power Supply N69100 Series Operating and Service Guide...
Страница 2: ......
Страница 14: ......
Страница 50: ...Outline Diagram for 10 kW Models 1 Quick Reference 50 Keysight N69100 Series Operating and Service Guide...
Страница 51: ...Outline Diagram for 20 kW Models Keysight N69100 Series Operating and Service Guide 51 1 Quick Reference...
Страница 52: ......
Страница 80: ......
Страница 94: ......
Страница 210: ...Status Diagram 5 SCPI Programming Reference 210 Keysight N69100 Series Operating and Service Guide...
Страница 212: ...Trigger Diagram 5 SCPI Programming Reference 212 Keysight N69100 Series Operating and Service Guide...
Страница 230: ...Models N69172A and N69173A 6 Verification and Calibration 230 Keysight N69100 Series Operating and Service Guide...
Страница 244: ......