OUTPut[:STATe]:COUPle:DOFFset <
value
>|MIN|MAX
OUTPut[:STATe]:COUPle:DOFFset? [MIN|MAX]
Sets a delay offset to synchronize coupled output state changes. Units are in seconds. Setting this
time to the maximum delay offset specified for any instrument that is being coupled will cause all
coupled outputs to synchronize to the turn-on times specified by OUTPut:DELay:RISE. This parameter
is saved in non-volatile memory.
Parameter
Typical Return
0 to 1.023
<delay value>
Specifies a delay of 60 milliseconds: OUTP:COUP:DOFF 0.06
OUTPut[:STATe]:COUPle:MAX:DOFFset?
Returns the delay offset required for this instrument. As a minimum, the
OUTPut:COUPle:DELay:OFFSet value must be set to the maximum delay offset returned for any
coupled output.
Parameter
Typical Return
(none)
<offset value>
Returns the maximum delay offset: OUTP:COUP:MAX:DOFF?
OUTPut[:STATe]:DELay:FALL <
value
>|MIN|MAX
OUTPut[:STATe]:DELay:FALL? [MIN|MAX]
OUTPut[:STATe]:DELay:RISE <
value
>|MIN|MAX
OUTPut[:STATe]:DELay:RISE? [MIN|MAX]
Specifies the delay in seconds that the instrument waits before turning the output on (rise) or off (fall).
This allows multiple instruments to turn on or off in sequence. The output will not turn on or off until
its delay time has elapsed. This command affects on-to-off state transitions. It does NOT affect
transitions to off caused by protection functions. Delay times can be programmed with the following
resolution:
Range in seconds
Resolution
Range in seconds
Resolution
0 to 1.023E–4
100 nanoseconds
1.03E–1 to 1.023E+0
1 millisecond
1.03E–4 to 1.023E–3
1 microsecond
1.03E+0 to 1.023E+1
10 milliseconds
1.03E–3 to 1.023E–2
10 microseconds
1.03E+1 to 1.023E+2
100 milliseconds
1.03E–2 to 1.023E–1
100 microseconds
1.03E+2 to 1.023E+3
1 second
Note that both Rise and Fall commands use the same resolution; which is determined by whichever
delay time (fall or rise) is the longest.
Keysight N69100 Series Operating and Service Guide
185
5 SCPI Programming Reference
Содержание N69100 Series
Страница 1: ...Keysight Advanced Power System DC Power Supply N69100 Series Operating and Service Guide...
Страница 2: ......
Страница 14: ......
Страница 50: ...Outline Diagram for 10 kW Models 1 Quick Reference 50 Keysight N69100 Series Operating and Service Guide...
Страница 51: ...Outline Diagram for 20 kW Models Keysight N69100 Series Operating and Service Guide 51 1 Quick Reference...
Страница 52: ......
Страница 80: ......
Страница 94: ......
Страница 210: ...Status Diagram 5 SCPI Programming Reference 210 Keysight N69100 Series Operating and Service Guide...
Страница 212: ...Trigger Diagram 5 SCPI Programming Reference 212 Keysight N69100 Series Operating and Service Guide...
Страница 230: ...Models N69172A and N69173A 6 Verification and Calibration 230 Keysight N69100 Series Operating and Service Guide...
Страница 244: ......