Keysight N69146A
N69146A
Test Record
Report Number ______
Date__________
Test Description
Model
Min. Specs
Results
Max. Specs
Voltage Programming & Readback
Minimum voltage (Vout):
Voltage measured over interface:
High voltage (Vout):
Voltage measured over interface:
Both
Both
Both
Both
0.133968
Vout - 0.026032
159.942
Vout - 0.058
_______
_______
_______
_______
0.186032
Vout + 0.026032
160.058
Vout + 0.058
CV Load Effect:
Both
- 0.006
_______
+ 0.006
CV Ripple and Noise
peak-to-peak:
rms:
Both
Both
N/A
N/A
_______
_______
0.200
0.020
Transient response @ 900 µs:
Both
- 1.6
_______
+ 1.6
Current Programming & Readback
Minimum current (Iout):
Current measured over interface:
High current (Iout):
Current measured over interface:
Both
Both
Both
Both
- 0.058
Iout - 0.058
124.867
Iout - 0.133
_______
_______
_______
_______
0.058
Iout + 0.058
125.133
Iout + 0.133
CC Load Effect:
Both
- 0.013
_______
+ 0.013
Current Sink Tests
10% of current rating:
Both
-12.8157
_______
-12.6844
N69146A UUT Settings
RP7946A Load Settings
Voltage Programming & Readback Min:
Voltage Programming & Readback High:
CV Load Effect, CV Ripple and Noise:
Transient Response:
Current Programming & Readback Min:
Current Programming & Readback High:
CC Load Effect:
10% of current rating (Isink):
Voltage priority: 0.16 V, 63.75 A
Voltage priority: 160 V, 63.75 A
Voltage priority: 80 V, 125 A
Voltage priority: 80 V, 62.5 A
Current priority: 80.8 V, 0 A
Current priority: 80.8 V, 125 A
Current priority: 161.6 V, 62.5 A
Voltage priority: 0 V, 0 A
not used
not used
Current priority: 80.8 V, -125 A
Current priority: 120 V, -50 A to -112.5 A, slew=2 A/µs
Voltage priority: 80 V, 0 A
Voltage priority: 80 V, -127.5 A
Voltage priority: 160 V, -63.75 A
Voltage priority: 80 V, 125 A
Keysight N69100 Series Operating and Service Guide
241
6 Verification and Calibration
Содержание N69100 Series
Страница 1: ...Keysight Advanced Power System DC Power Supply N69100 Series Operating and Service Guide...
Страница 2: ......
Страница 14: ......
Страница 50: ...Outline Diagram for 10 kW Models 1 Quick Reference 50 Keysight N69100 Series Operating and Service Guide...
Страница 51: ...Outline Diagram for 20 kW Models Keysight N69100 Series Operating and Service Guide 51 1 Quick Reference...
Страница 52: ......
Страница 80: ......
Страница 94: ......
Страница 210: ...Status Diagram 5 SCPI Programming Reference 210 Keysight N69100 Series Operating and Service Guide...
Страница 212: ...Trigger Diagram 5 SCPI Programming Reference 212 Keysight N69100 Series Operating and Service Guide...
Страница 230: ...Models N69172A and N69173A 6 Verification and Calibration 230 Keysight N69100 Series Operating and Service Guide...
Страница 244: ......