Parameter
Typical Return
(none)
1
Return a 1 when commands complete: *OPC?
l
The purpose of this command is to synchronize your application with the instrument.
l
Other commands cannot be executed until this command completes.
*OPT?
Returns a string identifying any installed options. A 0 (zero) indicates no options are installed.
Parameter
Typical Return
(none)
OPT 760
Returns installed options *OPT?
*RCL <0-9>
Recalls a saved instrument state. This restores the instrument to a state that was previously stored in
locations 0 through 9 with the *SAV command. All instrument states are recalled except: (1) the output
state is set to OFF, (2) the trigger systems are set to the Idle state, (3) calibration is disabled, (4) all
lists are set to their *RST values, and (5) the non-volatile settings are not affected.
Parameter
Typical Return
0 - 9
(none)
Recall state from location 1: *RCL 1
l
Location 0 is automatically recalled at power turn-on when the Output Power-On state is set to
RCL 0.
l
Stored instrument states are not affected by *RST.
*RST
Resets the instrument to pre-defined values that are either typical or safe. These settings are
described in
Parameter
Typical Return
(none)
(none)
Reset the instrument: *RST
l
*RST forces the ABORt commands. This cancels any measurement or transient actions presently
in process. It resets the WTG-meas, MEAS-active, WTG-tran, and TRAN-active bits in the Oper-
ation Status registers.
5 SCPI Programming Reference
172
Keysight N69100 Series Operating and Service Guide
Содержание N69100 Series
Страница 1: ...Keysight Advanced Power System DC Power Supply N69100 Series Operating and Service Guide...
Страница 2: ......
Страница 14: ......
Страница 50: ...Outline Diagram for 10 kW Models 1 Quick Reference 50 Keysight N69100 Series Operating and Service Guide...
Страница 51: ...Outline Diagram for 20 kW Models Keysight N69100 Series Operating and Service Guide 51 1 Quick Reference...
Страница 52: ......
Страница 80: ......
Страница 94: ......
Страница 210: ...Status Diagram 5 SCPI Programming Reference 210 Keysight N69100 Series Operating and Service Guide...
Страница 212: ...Trigger Diagram 5 SCPI Programming Reference 212 Keysight N69100 Series Operating and Service Guide...
Страница 230: ...Models N69172A and N69173A 6 Verification and Calibration 230 Keysight N69100 Series Operating and Service Guide...
Страница 244: ......