![Keysight Technologies N69100 Series Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/keysight-technologies/n69100-series/n69100-series_operating-and-service-manual_1962218028.webp)
[:LEVel] <
value
>{,<
value
>}|
<Block>
Specifies the level of each point in the Arb.
:DWELl <
value
>
Specifies the dwell time of each point in the Arb.
:POINts?
Returns the number of points in the Arb.
[SOURce:]
[:LEVel]
[:IMMediate]
[:AMPLitude] <
value
>
Sets the output current when in current priority mode.
:TRIGgered
[:AMPLitude] <
value
>
Sets the triggered output current.
:BWIDth
:RANGe 0|1
Sets the current compensation. Only applies to models N6914xA
:LIMit
[:POSitive]
[:IMMediate]
[:AMPLitude] <
value
>
Sets the current limit when in voltage priority mode.
:NEGative
[:IMMediate]
[:AMPLitude] <
value
>
Sets the current limit when in voltage priority mode.
:MODE FIXed|STEP|LIST|ARB
Sets the transient mode.
:PROTection
:DELay
[:TIME] <
value
>
Sets the over-current protection delay.
:STARt SCHange|CCTRans
Specifies what starts the over-current protection delay timer.
:STATe 0|OFF|1|ON
Enables or disables the over-current protection.
:SLEW
[:IMMediate] <
value
>|INFinity
Sets the current slew rate.
:MAXimum 0|OFF|1|ON
Enables or disables the maximum slew rate override.
[SOURce:]
:INPut
:DATA?
Reads the state of the digital control port.
:OUTPut
:DATA <
value
>
Sets the state of the digital control port.
:PIN<1-7>
:FUNCtion <
function
>
Sets pin function. DIO|DINPut|FAULt|INHibit|ONCouple|OFFCouple |TOUTput|TINPut
:POLarity POSitive|NEGative
Sets the pin polarity.
:TOUTput
:BUS
[:ENABle] 0|OFF|1|ON
Enables or disables BUS triggers on digital port pins.
[SOURce:]
1 Quick Reference
28
Keysight N69100 Series Operating and Service Guide
Содержание N69100 Series
Страница 1: ...Keysight Advanced Power System DC Power Supply N69100 Series Operating and Service Guide...
Страница 2: ......
Страница 14: ......
Страница 50: ...Outline Diagram for 10 kW Models 1 Quick Reference 50 Keysight N69100 Series Operating and Service Guide...
Страница 51: ...Outline Diagram for 20 kW Models Keysight N69100 Series Operating and Service Guide 51 1 Quick Reference...
Страница 52: ......
Страница 80: ......
Страница 94: ......
Страница 210: ...Status Diagram 5 SCPI Programming Reference 210 Keysight N69100 Series Operating and Service Guide...
Страница 212: ...Trigger Diagram 5 SCPI Programming Reference 212 Keysight N69100 Series Operating and Service Guide...
Страница 230: ...Models N69172A and N69173A 6 Verification and Calibration 230 Keysight N69100 Series Operating and Service Guide...
Страница 244: ......