Fault Output
Pins 1 and 2 can be configured as a fault-output pair. The Fault Output function enables a fault
condition to generate a protection fault signal on the digital port. Refer to
for a list of protection signals.
Both pins 1 and 2 are dedicated to this function. Pin 1 is the Fault output; pin 2 is the common for pin 1.
This provides for an optically-isolated output. The polarity of pin 1 can also be configured. When the
pin polarity is POSitive, a fault condition causes the isolated output to conduct. Note that the Fault
output signal remains latched until the fault condition is removed and the protection circuit is cleared.
as explained under
Pin 2's selected function is ignored. Pin 2 should be connected to the ground of the
external circuit.
Front Panel Menu Reference
SCPI Command
Select
System\IO\DigPort\Pins
.
Select pin 1, then Function, then Fault Out.
In the Polarity field, select either Positive or Negative.
To configure the Fault function:
To select the pin polarity:
Inhibit Input
Pin 3 can be configured as a remote inhibit input. The Inhibit Input function lets an external input signal
control the output state of instrument. The input is level triggered. The signal latency is 5
microseconds. Pin 8 is the common for pin 3. The following non-volatile inhibit input modes can be
programmed:
LATChing - causes a logic-true transition on the Inhibit input to disable the output. The output will
remain disabled after the inhibit signal is received.
LIVE - allows the enabled output to follow the state of the Inhibit input. When the Inhibit input is true,
the output is disabled. When the Inhibit input is false, the output is re-enabled.
OFF - The Inhibit input is ignored.
To configure the Inhibit Input function:
Front Panel Menu Reference
SCPI Command
Select
System\IO\DigPort\Pins
.
Select pin 3, then Function, then Inhibit In.
In the Polarity field, select either Positive or Negative.
Select
Protect\Inhibit
.
Select either Latching or Live.
To disable the Inhibit signal, select Off.
To select the Inhibit function:
To select the pin polarity:
To specify the Inhibit mode:
OUTP:INH:MODE LATC
OUTP:INH:MODE LIVE
OUTP:INH:MODE OFF
Keysight N69100 Series Operating and Service Guide
137
4 Using the DC Power System
Содержание N69100 Series
Страница 1: ...Keysight Advanced Power System DC Power Supply N69100 Series Operating and Service Guide...
Страница 2: ......
Страница 14: ......
Страница 50: ...Outline Diagram for 10 kW Models 1 Quick Reference 50 Keysight N69100 Series Operating and Service Guide...
Страница 51: ...Outline Diagram for 20 kW Models Keysight N69100 Series Operating and Service Guide 51 1 Quick Reference...
Страница 52: ......
Страница 80: ......
Страница 94: ......
Страница 210: ...Status Diagram 5 SCPI Programming Reference 210 Keysight N69100 Series Operating and Service Guide...
Страница 212: ...Trigger Diagram 5 SCPI Programming Reference 212 Keysight N69100 Series Operating and Service Guide...
Страница 230: ...Models N69172A and N69173A 6 Verification and Calibration 230 Keysight N69100 Series Operating and Service Guide...
Страница 244: ......