1A-254 Engine Control System (4HK1)
DTC P1669 (Flash Code 75)
Circuit Description
The diesel particulate defuser (DPD) lamp is located on
the instrument panel (IP) cluster. The DPD lamp
informs the driver that an incomplete automatic
regeneration has occurred and manual regeneration is
required.
The ECM monitors the DPD lamp control circuit for
conditions that are incorrect for the commanded state
of the DPD lamp. For example, a failure condition
exists if the ECM detects low voltage when the DPD
lamp is commanded OFF, or high voltage when the
DPD lamp is commanded ON. If the ECM detects an
improper voltage level on the control circuit, this DTC
will set.
Condition for Running the DTC
• The battery voltage is between 18 to 32 volts.
• The ignition switch is ON.
Condition for Setting the DTC
Either of following condition is met:
• The ECM detects a low voltage condition on the
DPD lamp control circuit when the lamp is
commanded OFF.
• The ECM detects a high voltage condition on the
DPD lamp control circuit when the lamp is
commanded ON.
Action Taken When the DTC Sets
• The ECM will illuminate the SVS lamp. Refer to
DTC Type Definitions for Action Taken When the
DTC Sets - Type C.
Condition for Clearing the DTC
• Refer to DTC Type Definitions for Condition for
Clearing the SVS Lamp/ DTC - Type C.
Diagnostic Aids
• If an intermittent condition is suspected, refer to
Intermittent Conditions in this section.
Schematic Reference:
Engine Controls Schematics
Connector End View Reference:
Engine Controls
Connector End Views or ECM Connector End Views
Circuit/ System Testing DTC P1669
Step
Action
Value(s)
Yes
No
1
Did you perform the Diagnostic System Check
- Engine Controls?
—
Go to Step 2
Go to Diagnostic
System Check -
Engine Controls
2
1.
Verify whether the instrument panel (IP)
cluster is operational.
2.
Install a scan tool.
3.
Turn OFF the ignition for 30 seconds.
4.
Turn ON the ignition for 40 seconds while
observing the DTC Information with a scan
tool.
Does the DTC fail this ignition?
—
Go to Step 3
Go to Diagnostic
Aids
3
1.
Turn OFF the ignition.
2.
Inspect the Meter (10A) fuse in the cab.
Is the Meter (10A) fuse open?
—
Go to Step 4
Go to Step 5
4
Replace the Meter (10A) fuse. If the fuse continues
to open, repair the short to ground on one of the
circuits that is fed by the Meter (10A) fuse or
replace the shorted attached component.
Did you complete the repair?
—
Go to Step 17
—
5
1.
Turn OFF the ignition.
2.
Disconnect the ECM J-14 harness connector.
3.
Turn ON the ignition, with the engine OFF.
Is the DPD lamp OFF?
—
Go to Sep 6
Go to Step 12
LG4HKED-WE-0871.book 254
ページ
2007年11月29日 木曜日 午後6時29分
Содержание 2008MY N Series
Страница 3: ......
Страница 401: ...MEMO LG4HKED WE 0871 book 1...
Страница 403: ......
Страница 404: ...WORKSHOP MANUAL ENGINE CONTROL SYSTEM 4HK1 model No LG4HKED WE 0871 WORKSHOP MANUAL ENGINE CONTROL SYSTEM 4HK1 model...