2-45
Replace the stator (P. 11-5).
Replace the stator (P. 11-5).
d. GENERATOR
• No AC Output
Check whether an error code is displayed on the i-Monitor.
Refer to "FAILURE BY ERROR
CODE" troubleshooting (P. 2-11).
Check whether the output indicator is on.
Check the control panel:
• Check the main wire harness for open or short circuit and for
proper connection.
• Check the voltage selector switch (P. 6-11).
Check the generator (P. 11-7).
Check the harness connecting the generator and inverter unit
for open or short circuit and for proper connection.
Wire harness check points
R
Bu
W
R
Bu
W
Viewed from terminal side
GENERATOR
SLAVE
GENERATOR
MASTER
GENERATOR WIRE HARNESS
INVERTER
UNIT
RED TAPE
MARKS
Bu: BLUE
W: WHITE
R: RED
Go to P. 2-46
Normal
Normal
Displayed
Not displayed
On
Normal
Off
Abnormal
Abnormal
Abnormal
INVERTER
UNIT
• Replace or repair the main wire
harness.
• Replace the voltage selector
switch (P. 6-6).
Turn the ignition switch OFF and then start the engine and
recheck. Replace the inverter unit if necessary (P. 6-2).
cap.02 EU65is 6500is-2 (E) 07.12.17 5:56 PM ページ2-45