2-15
(Starter motor failure)
E-00
Check the battery (P. 5-1).
Replace or recharge the battery
(P. 5-1 and 2).
Good
Check the ignition pulse generator air gap (P. 11-4).
Adjust the ignition pulse
generator air gap (P. 11-4).
Normal
Abnormal
Abnormal
Check the ignition pulse generator (P. 11-4).
Replace the ignition pulse
generator (P. 11-3).
Normal
Check the harness connecting the ignition pulse generator and
GCU for open or short circuit and for proper connection.
Replace or repair the wire
harness.
Abnormal
Abnormal
GND5
C21
C22
IGNITION
PULSE
GENERATOR
Y/Bu
Y/Bu
Bu
Bl
ENGINE WIRE
HARNESS
CONTROL WIRE HARNESS
G
G
GCU
Viewed from terminal side
Wire harness check points
Normal
To P. 2-16
Y: YELLOW
Bu: BLUE
G: GREEN
cap.02 EU65is 6500is (Eu).qxd 07.12.17 4:25 PM ページ2-15