b. INSPECTION
• INVERTER UNIT
Check for continuity between the terminals using a tester with
diode measuring function according to the tables below.
• Set
mark position of a tester and perform this inspection.
• The "no continuity" display varies on each tester. When there
is no continuity, the display shows the same as it does when
the tester is not used for measurement (OL, OF, etc).
• Some testers have reverse polarity.
[1] (+) Tester probe
[2] Connector
[4] Terminal
1
2
1
[5] No continuity
[5] No continuity
2
[5] No continuity
[5] No continuity
3
[5] No continuity
[5] No continuity
4
[5] No continuity
[5] No continuity
6
0.35 – 0.8 V
0.35 – 0.8 V