2-26
, , , , ,
,
,
,
,
(GCU internal failure or inverter unit internal failure)
E-2b
E-2A
E-29
E-28
E-27
E-1b
E-1A
E-19
E-18
E-17
Check the generator (P. 11-7).
Replace the stator (P. 11-5).
Normal
Abnormal
Check the main wire harness in the control box for open or
short circuit and for proper connection.
Replace or repair the main wire
harness.
Normal
Abnormal
Normal
Check the inverter unit (P. 6-3 and 4).
Replace the inverter unit (P. 6-2).
Abnormal
Normal
Turn the ignition switch OFF and then restart the engine and
check the error code. If the same error occurs, replace the GCU
(P. 6-6).
Check the harness connecting the inverter unit and generator
for open or short and for proper connection.
Wire harness check points
Viewed from terminal side
GENERATOR
(SLAVE)
GENERATOR
(MASTER)
GENERATOR WIRE HARNESS
INVERTER
UNIT
INVERTER
UNIT
Bu: BLUE
R: RED
W: WHITE
Replace or repair the generator
wire harness.
Abnormal
R
Bu
W
R
Bu
W