2-12
a. TROUBLESHOOTING BY ERROR CODE
No Indicator Light and i-Monitor Does Not Display
When turning the ignition switch to ON, i-Monitor and three indicators will blink. The generator is running, and the
output indicator and i-Monitor display will remain lit.
Check the fuses (MAIN 15A, ACC 1A).
Replace the fuse (P. 6-5).
Normal
Blown
Check the ignition switch (P. 6-11).
Check the harness connecting the ignition switch and GCU for
open or short circuit and for proper connection.
Replace the ignition switch (P. 6-6
thru. 10).
Normal
Abnormal
Replace or repair the engine wire
harness and/or control wire
harness.
Abnormal
Normal
Turn the ignition switch OFF and then restart the engine and
check the error code. If the same error occurs, replace the GCU
(P. 6-6).
IGNITION
SWITCH
Br/W
Br/W
Bl/Y
Bl/Y
Bl/Y
ENGINE WIRE
HARNESS
CONTROL WIRE HARNESS
Viewed from terminal side
Wire harness check points
GCU
FUSE 1A
FUSE 15A
Bl: BLACK
Y: YELLOW
W: WHITE
Br: BROWN
cap.02 EU65is 6500is (Eu).qxd 07.12.17 4:25 PM ページ2-12