14-10
<CAM HEIGHT>
• OIL LEVEL SWITCH
Check for continuity between the switch lead and switch body
with an ohmmeter.
1) Hold the switch in its normal position. The ohmmeter
should read less than 100
Ω
resistance.
2) Hold the switch upside down. There should be no
continuity.
3) Hold the switch in the normal position. Check that the
continuity stops when completely immersing the switch in
a container of oil.
Standard
Service limit
IN
32.40 – 32.80 mm
32.25 mm
(1.276 – 1.291 in)
(1.270 in)
EX
31.89 – 32.29 mm
31.75 mm
(1.256 – 1.271 in)
(1.250 in)