Command Manual (For Soliton) – HWPing
H3C S3100 Series Ethernet Switches
Chapter 1 HWPing Commands
1-9
# Display the result of the test group with the administrator name being administrator,
and the operation tag being Jitter.
[Sysname-hwping-administrator-Jitter] display hwping results administrator
Jitter
HWPing entry(admin administrator, tag Jitter) test result:
Destination ip address:10.2.2.2
Send operation times: 100 Receive response times: 100
Min/Max/Average Round Trip Time: 9/21/13
Square-Sum of Round Trip Time: 18623
Last succeeded test time: 2000-4-2 8:14:58.2
Extend result:
SD Maximal delay: 10 DS Maximal delay: 10
Packet lost in test: 0%
Disconnect operation number: 0 Operation timeout number: 0
System busy operation number: 0 Connection fail number: 0
Operation sequence errors: 0 Drop operation number: 0
Other operation errors: 0
Jitter result:
RTT Number:100
Min Positive SD:1 Min Positive DS:1
Max Positive SD:6 Max Positive DS:8
Positive SD Number:38 Positive DS Number:25
Positive SD Sum:85 Positive DS Sum:42
Positive SD average:2 Positive DS average:1
Positive SD Square Sum:267 Positive DS Square Sum:162
Min Negative SD:1 Min Negative DS:1
Max Negative SD:6 Max Negative DS:8
Negative SD Number:30 Negative DS Number:24
Negative SD Sum:64 Negative DS Sum: 41
Negative SD average:2 Negative DS average:1
Negative SD Square Sum:200 Negative DS Square Sum:161
SD lost packets number:0 DS lost packet number:0
Unkown result lost packet number:0
Table 1-5
Description on the fields of the
display hwping result
command
Field
Description
RTT Number
Number of received response packets
Min Positive SD
Minimum positive jitter delay from the source to the
destination
Min Positive DS
Minimum positive jitter delay from the destination to the
source