Command Manual (For Soliton) – SNMP-RMON
H3C S3100 Series Ethernet Switches
Chapter 2 RMON Configuration Commands
2-14
2.1.10 rmon prialarm
Syntax
rmon prialarm entry-number prialarm-formula prialarm-des sampling-timer
{
delta
|
absolute
|
changeratio
}
rising_threshold threshold-value1 event-entry1
falling_threshold threshold-value2 event-entry2 entrytype
{
forever
|
cycle
cycle-period
} [
owner text
]
undo rmon prialarm entry
-
number
View
System view
Parameters
entry
-
number
: Extended alarm entry index, in the range 1 to 65535.
prialarm-formula
: Expression used to perform operations on the alarm variables, a
string of 1 to 256 characters. The alarm variables in the expression must be
represented by OIDs, for example, (.1.3.6.1.2.1.2.1.10.1)*8. The operations available
are addition, subtraction, multiplication and division operations. The operation results
are rounded to values that are of long integer type. To prevent invalid operation results,
make sure the operation results of each step are valid long integers.
prialarm-des
: Alarm description, a string of 1 to 128 characters.
sampling
-
timer
: Sampling interval (in seconds), in the range 10 to 65535.
delta
|
absolute
|
changeratio
: Specifies the sample type.
threshold
-
value1
: Upper threshold, in the range 0 to 2147483647.
event
-
entry1
: Index of the event entry that corresponds to the rising threshold, in the
range 0 to 65535.
threshold
-
value2
: Lower threshold, in the range 0 to 2147483647.
event
-
entry2
: Index of the event entry that corresponds to the falling threshold, in the
range 0 to 65535.
forever
: Specifies the corresponding RMON alarm instance is valid permanently.
cycle
: Specifies the corresponding RMON alarm instance is valid periodically.
cycle
-
period
: Life time (in seconds) of the RMON alarm instance, in the range 0 to
2147483647.
owner text
: Specifies the owner of the alarm entry, a string of 1 to 127 characters.
Description
Use the
rmon prialarm
command to create an extended entry in an extended RMON
alarm table. If you do not specify the
owner text
keyword/argument combination, the
owner of the entry is displayed as “null”.