Command Manual (For Soliton) – SNMP-RMON
H3C S3100 Series Ethernet Switches
Chapter 1 SNMP Configuration Commands
1-1
Chapter 1 SNMP Configuration Commands
Note:
z
The configuration of creating a MIB view with the mask of a MIB subtree is added.
See section
snmp-agent mib-view
for details.
z
The configuration of encrypting a plain-text password is added. See section
snmp-agent calculate-password
.
z
The configuration of adding “interface description” and “interface type” into a
linkUp/linkDown trap is added. See section
1.1.21 snmp-agent trap ifmib
.
1.1 SNMP Configuration Commands
1.1.1 display snmp-agent
Syntax
display snmp-agent
{
local-engineid
|
remote-engineid
}
View
Any view
Parameters
local-engineid
: Displays the local SNMP entity engine ID.
remote-engineid
: Displays all the remote SNMP entity engine IDs. At present, the
device does not support application of the keyword.
Description
Use the
display snmp-agent
command to display the local SNMP entity engine ID or
all the remote SNMP entity engine IDs.
Each device managed by the NMS needs a unique engine ID to identify an SNMP
agent. By default, each device has a default engine ID. You should ensure that each
engine ID is unique within an SNMP domain.
The creation of username and generation of cipher text password are related to engine
ID in SNMPv3. If you change an engine ID, the username and password configured on
the agent with this engine ID become invalid.