![H3C S3100 Series Скачать руководство пользователя страница 925](http://html1.mh-extra.com/html/h3c/s3100-series/s3100-series_command-manual_3591810925.webp)
Command Manual (For Soliton) – System Maintenance and Debugging
H3C S3100 Series Ethernet Switches
Chapter 3 Device Management
Commands
3-11
Table 3-7
Description on the fields of display transceiver diagnosis interface
Field
Description
transceiver diagnostic information
Digital diagnosis information of the
transceiver carried by an interface
Current diagnostic parameters
Current diagnostic parameters
Temp.(°C)
Digital diagnosis parameter-temperature, in
°C, with the precision to 1°C.
Voltage(V)
Digital diagnosis parameter-voltage, in V, with
the precision to 0.01 V.
Bias(mA)
Digital diagnosis parameter-bias current, in
mA, with the precision to 0.01 mA.
RX power(dBM)
Digital diagnosis parameter-RX power, in
dBM, with the precision to 0.01 dBM.
TX power(dBM)
Digital diagnosis parameter-TX power, in
dBM, with the precision to 0.01 dBM.
3.1.11 display transceiver interface
Syntax
display transceiver interface
[
interface-type
interface-number
]
View
Any view
Parameters
interface-type interface-number:
Interface type and interface number.
Description
Use the
display transceiver interface
command to display main parameters of a
single or all transceivers.
Examples
# Display main parameters of the pluggable transceiver on interface GigabitEthernet
1/1/2.
<Sysname> display transceiver interface gigabitethernet 1/1/2
GigabitEthernet1/1/2 transceiver information:
Transceiver Type : 1000_BASE_LX_SFP
Connector Type : LC
Wavelength(nm) : 1310
Transfer Distance(km) : 10(9um)