Command Manual (For Soliton) – SNMP-RMON
H3C S3100 Series Ethernet Switches
Chapter 2 RMON Configuration Commands
2-2
Field
Description
Valid
The alarm entry identified by the index is valid.
Samples type
Sampling type, which can be absolute or delta
Variable formula
The sampled node
Sampling interval
Sampling interval, in seconds. The system performs
absolute or delta sampling on the sampled node at
this interval.
Rising threshold
Rising threshold. When the sampled value equals or
exceeds the rising threshold, an alarm is triggered.
Falling threshold
Falling threshold. When the sampled value equals or
falls under the falling threshold, an alarm is triggered.
When startup enables
The condition under which an alarm is triggered,
which can be:
z
risingOrFallingAlarm: An alarm is triggered when
the rising or falling threshold is reached.
z
risingAlarm: An alarm is triggered when the rising
threshold is reached.
z
FallingAlarm: An alarm is triggered when the
falling threshold is reached.
Latest value
The value of the latest sample
2.1.2 display rmon event
Syntax
display rmon event
[
event
-
entry
]
View
Any view
Parameters
event
-
entry
: RMON event entry index, in the range 1 to 65535. If you do not specify the
event
-
entry
argument, the configuration of all the RMON event entries is displayed.
Description
Use the
display rmon event
command to display the configuration of a specified
RMON event entry.
RMON event information includes the following:
z
Event entry index
z
Event entry owner
z
Event description