GE Power Management
MM2 Motor Manager 2
6-23
6 COMMUNICATIONS
6.5 MEMORY MAP
6
TIMERS
30113
112
0070 Undervoltage Restart Timer
---
---
0.1 x s
F1
N/A
30114
113
0071 AUX1 Post Contactor A Delay Timer
---
---
s
F1
N/A
30115
114
0072 Transfer Timer
---
---
0.5 x s
F1
N/A
30116
115
0073 First Stage Timer
---
---
0.5 x s
F1
N/A
30117
116
0074 Second Stage Timer
---
---
0.5 x s
F1
N/A
30118
117
0075 Start Inhibit Timer
---
---
s
F1
N/A
30119
118
0076 AUX2 Post Contactor A Delay Timer
---
---
s
F1
N/A
30120
119
0077 AUX 1+2 Pre Con. A Delay Timer
---
---
s
F1
N/A
30121
120
0078 AUX1 Pre Con A Post Start Dly Timer
---
---
s
F1
N/A
30122
121
0079 AUX2 Pre Con A Post Start Dly Timer
---
---
s
F1
N/A
30123
122
007A ...Reserved...
...
...
...
...
...
↓
↓
↓
↓
↓
↓
↓
↓
↓
30128
127
007F ...Reserved...
...
...
...
...
...
DEBUG
DATA
30129
128
0080 ADC Reference
---
---
---
F1
N/A
30130
129
0081 Thermistor Reading
---
---
kOhms
F1
N/A
30131
130
0082 Power Loss Fine Time
---
---
10 ms
F1
N/A
30132
131
0083 Power Loss Coarse Time
---
---
0.1 min
F1
N/A
30133
132
0084 Current key press
---
---
---
F24
N/A
30134
133
0085 Internal Fault Error Code
---
---
---
---
N/A
30135
134
0086 Phase A Current (fast update)
---
---
**
F1
N/A
30136
135
0087 Phase B Current (fast update)
---
---
**
F1
N/A
30137
136
0088 Phase C Current (fast update)
---
---
**
F1
N/A
30138
137
0089 Ground Current (fast update)
---
---
0.1 x A
F1
N/A
30139
138
008A Voltage (fast update)
---
---
V
F1
N/A
30140
139
008B Current Display Line
---
---
---
F1
N/A
30141
140
008C Current Display Mode
---
---
---
F1
N/A
30142
141
008D ...Reserved...
...
...
...
...
...
30143
142
008E ...Reserved...
...
...
...
...
...
30144
143
008F ...Reserved...
...
...
...
...
...
30145
144
0090 Message Buffer characters 1 and 2
---
---
ASCII
F10
N/A
30146
145
0091 Message Buffer characters 3 and 4
---
---
ASCII
F10
N/A
30147
146
0092 Message Buffer characters 5 and 6
---
---
ASCII
F10
N/A
30148
147
0093 Message Buffer characters 7 and 8
---
---
ASCII
F10
N/A
30149
148
0094 Message Buffer characters 9 and 10
---
---
ASCII
F10
N/A
Table 6–12: MODBUS MEMORY MAP (Sheet 4 of 21)
GROUP
MOD-
ICON
REGISTER
ADDRESS
DESCRIPTION
REGISTE
R VALUE
RANGE
STEP
VALUE
UNITS
AND
SCALE
FOR-
MAT
FACTORY
DEFAULT
VALUE
(CONVERTED)
DEC
HEX
Notes: * – Maximum setpoint value and 65535 represent OFF
** – 1/Phase Current Scale Factor x A
*** – 101 represents unlimited
† – Minimum setpoint value represents OFF
~* – 0.1 x A when Hi resolution mode is disabled; 0.01 x A when enabled
Содержание MOTOR MANAGER 2
Страница 2: ......
Страница 4: ......
Страница 21: ...GE Power Management MM2 Motor Manager 2 2 3 2 INSTALLATION 2 1 MOUNTING 2 Figure 2 4 TYPICAL WIRING DIAGRAM ...
Страница 33: ...GE Power Management MM2 Motor Manager 2 3 7 3 HARDWARE 3 3 THEORY OF OPERATION 3 Figure 3 2 BLOCK DIAGRAM ...
Страница 34: ...3 8 MM2 Motor Manager 2 GE Power Management 3 3 THEORY OF OPERATION 3 HARDWARE 3 ...
Страница 80: ...5 12 MM2 Motor Manager 2 GE Power Management 5 5 A4 STATISTICS 5 ACTUAL VALUES 5 ...
Страница 130: ...7 2 MM2 Motor Manager 2 GE Power Management 7 1 INJECTION TESTING 7 TESTING 7 Figure 7 1 SECONDARY INJECTION TEST SETUP ...
Страница 153: ...GE Power Management MM2 Motor Manager 2 9 5 9 STARTER TYPES 9 2 FV REVERSING STARTER 9 Figure 9 4 FV REVERSING STARTER ...
Страница 161: ...GE Power Management MM2 Motor Manager 2 9 13 9 STARTER TYPES 9 4 SLIP RING STARTER 9 Figure 9 10 SLIP RING STARTER ...
Страница 187: ...GE Power Management MM2 Motor Manager 2 9 39 9 STARTER TYPES 9 13 SOFT STARTER 9 Figure 9 25 SOFT STARTER ...
Страница 188: ...9 40 MM2 Motor Manager 2 GE Power Management 9 13 SOFT STARTER 9 STARTER TYPES 9 ...
Страница 212: ...E 4 MM2 Motor Manager 2 GE Power Management E 1 CT ISOLATION APPENDIXE E ...
Страница 220: ...iv MM2 Motor Manager 2 GE Power Management INDEX ...