6-44
MM2 Motor Manager 2
GE Power Management
6.6 DATA FORMATS
6 COMMUNICATIONS
6
F23
Unsigned Integer: Keypress
Simulation Data
FFFF
0x3100 = SETPOINT
---
0x3200 = ACTUAL
---
0x3300 = RESET
---
0x3400 = STORE
---
0x3500 = MESSAGE UP
---
0x3600 = MESSAGE DOWN
---
0x3700 = MESSAGE LEFT
---
0x3800 = MESSAGE RIGHT
---
0x3900 = VALUE UP
---
0x6100 = VALUE DOWN
---
F24
Unsigned Integer: Current key press
FFFF
0000 = no key
---
FE01 = AUTO
---
FE02 = MANUAL
---
FE04 = START A
---
FE08 = START B
---
FD01 = STOP 1
---
FD02 = STOP 2
---
FD04 = RESET
---
FD08 = STORE
---
FB01 = SETPOINT
---
FB02 = ACTUAL
---
FB04 = MESSAGE UP
---
FB08 = MESSAGE DOWN
---
F701 = MESSAGE LEFT
---
F702 = MESSAGE RIGHT
---
F704 = VALUE UP
---
F708 = VALUE DOWN
---
F25
Unsigned Integer: Modbus Baud Rate
FFFF
0 = 1200
---
1 = 2400
---
2 = 4800
---
3 = 9600
---
4 = 19200
---
Table 6–13: DATA FORMATS (Sheet 7 of 15)
CODE
DESCRIPTION
BITMASK
F26
Unsigned Integer: Relay / LED Test
Data
FFFF
0 = Normal operation mode
---
1 = Contactor A On
---
2 = Contactor B On
---
3 = AUX Relay 1 On
---
4 = AUX Relay 2 On
---
5 = All Relays On
---
6 = Running LED On
---
7 = Stopped LED On
---
8 = Tripped LED On
---
9 = Alarm LED On
---
10 = Fault LED On
---
11 = Auto LED On
---
12 = Manual LED On
---
13 = All LEDs On
---
14 = Flash Voltage On
---
F27
Unsigned Integer: Auto Mode
Definition
FFFF
0 = Serial
---
1 = Hard-Wired
---
F28
Unsigned Integer: Overload Curve
FFFF
1 = Curve # 1
---
2 = Curve # 2
---
3 = Curve # 3
---
4 = Curve # 4
---
5 = Curve # 5
---
6 = Curve # 6
---
7 = Curve # 7
---
8 = Curve # 8
---
9 = NEMA Class 10
---
10 = NEMA Class 15
---
11 = NEMA Class 20
---
12 = NEMA Class 30
---
F29
Unsigned Integer: ESD Indication
FFFF
0 = OFF when healthy
---
1 = ON when healthy
---
F30
Unsigned Integer:
Normally Open / Normally Closed
FFFF
0 = N.O.
---
1 = N.C.
---
Table 6–13: DATA FORMATS (Sheet 8 of 15)
CODE
DESCRIPTION
BITMASK
Содержание MOTOR MANAGER 2
Страница 2: ......
Страница 4: ......
Страница 21: ...GE Power Management MM2 Motor Manager 2 2 3 2 INSTALLATION 2 1 MOUNTING 2 Figure 2 4 TYPICAL WIRING DIAGRAM ...
Страница 33: ...GE Power Management MM2 Motor Manager 2 3 7 3 HARDWARE 3 3 THEORY OF OPERATION 3 Figure 3 2 BLOCK DIAGRAM ...
Страница 34: ...3 8 MM2 Motor Manager 2 GE Power Management 3 3 THEORY OF OPERATION 3 HARDWARE 3 ...
Страница 80: ...5 12 MM2 Motor Manager 2 GE Power Management 5 5 A4 STATISTICS 5 ACTUAL VALUES 5 ...
Страница 130: ...7 2 MM2 Motor Manager 2 GE Power Management 7 1 INJECTION TESTING 7 TESTING 7 Figure 7 1 SECONDARY INJECTION TEST SETUP ...
Страница 153: ...GE Power Management MM2 Motor Manager 2 9 5 9 STARTER TYPES 9 2 FV REVERSING STARTER 9 Figure 9 4 FV REVERSING STARTER ...
Страница 161: ...GE Power Management MM2 Motor Manager 2 9 13 9 STARTER TYPES 9 4 SLIP RING STARTER 9 Figure 9 10 SLIP RING STARTER ...
Страница 187: ...GE Power Management MM2 Motor Manager 2 9 39 9 STARTER TYPES 9 13 SOFT STARTER 9 Figure 9 25 SOFT STARTER ...
Страница 188: ...9 40 MM2 Motor Manager 2 GE Power Management 9 13 SOFT STARTER 9 STARTER TYPES 9 ...
Страница 212: ...E 4 MM2 Motor Manager 2 GE Power Management E 1 CT ISOLATION APPENDIXE E ...
Страница 220: ...iv MM2 Motor Manager 2 GE Power Management INDEX ...