SD20-G Series
139
b)
Related parameters
(1)
control mode selection
Parameters
Remarks
Po001
d □ 1
Control mode selection: position pulse command mode.
(2)
Input pulse command source
Parameters
Remarks
Po374
Four-parameter
b
A
0
1
Low-speed pulse source
B
0
1
C
0
1
Internal position pulse source
D
0
1
Pulse source of electronic cam
off
on
High-speed pulse source
off
on
off
on
off
on
Note: when setting Po374, user can set 1 to needed pulse source. If Po374.A=1, Po374.C=1, actual pulse
command=low speed pulse c internal position pulse command.
Start
Over
Low/high speed pulse input terminal
1. Dir pulse
3. Forward pulse + reverse pulse
Set pulse form
Confirm pulse input
terminal
Filter pulse input
terminal
Filter interference signal
1. Low-speed pulse filter: Po300.B
2. High-speed pulse filter: PL120.B.
2. Orthogonal pulse of A phase + B phase