Maintenance 6. Maintenance Parts Replacement Procedures
188
RC620 Rev.8
6.6 Switching Power Supply
6.6.1 Switching Power Supply (15W)
Switching
Power Supply
(15W)
Removal
(1) Turn OFF the Controller and unplug the power connector.
(2) Remove 10 screws and the top panel.
(3) Remove the Cable No. (4), (10)
connected with Switching Power
Supply (15W).
Refer to
Maintenance:
3.2
Diagram of Cable Connections
.
(4) Remove
4
screws securing the
Switching Power Supply and remove
the Power Supply.