4.2 Backup Data Types
The table below shows the files created with “Backup Controller”.
File Name
Overview
Backup.txt
Information file for
restore
File including information for restoring
the Controller.
CurrentMnp01.PRM
:
CurrentMnp16.PRM
Robot parameters
Stores information for each robot such as
TlSet.
InitFileSrc.txt
Initial configuration
Stores various Controller parameters.
MCSys01.MCD
:
MCSys16.MCD
Robot configuration Stores information for each connected
robot.
ProjectName.obj
OBJ file
Result of project building.
Prg file is not included.
All the files related
to Project
Project related
All the project files transferred to the
Controller. Includes program files when
EPSON RC+ 6.0 is configured to transfer
source code to the Controller.
GlobalPreserves.dat Global Preserve
variables
Stores
values of Global Preserve
variables.
ProjectName.vis
VisHWConfig.dat
Vision related
Stores the file when Vision Guide option
is used.
RCSam.dat
RC+ related
Stores the file when the security option is
used.
Содержание RC620 CU
Страница 1: ...Rev 8 EM15XC3076F ROBOT CONTROLLER RC620 ...
Страница 2: ...ROBOT CONTROLLER RC620 Rev 8 ...
Страница 17: ...Safety This section contains information for safety of the Robot System ...
Страница 18: ......
Страница 23: ...Setup Operation This section contains information for setup and operation of the Robot Controller ...
Страница 24: ...8 RC620 Rev 8 ...
Страница 137: ...Maintenance This section contains maintenance procedures for the Robot Controller ...
Страница 138: ......