Maintenance 6. Maintenance Parts Replacement Procedures
174
RC620 Rev.8
(6) Remove two screws for the COM panel
on the back panel.
(7) Remove the following connectors from
the CPU board (Faster).
Cable No. (21), (22), (23), COM1, 2
If RAID option is set:
Remove Cable No. (24)
If DVD drive is connected:
Remove Cable No. (25)
(22)-3: Remove in step (8)
(22)-1
(22)-2
(25)
(21)
COM1,2
(24)
(23)
Refer to
Maintenance: 3.2
Diagram of Cable Connections
.
(8) Slightly pull out the CPU board (Faster)
from PCI-BPB slot and while holding
the board with one hand, remove Cable
No. (22)-3.
Cable of the CPU board is connected
with PCI-BPB. Be sure to pull the
board slowly.
(22)-3
(9) Make sure all cables are disconnected and remove the CPU board from PCI-BPB slot.
NOTE