Setup & Operation 5. Memory Port
38
RC620 Rev.8
5.3.2 Controller Status Storage with Teach Pendant (Option)
Use this procedure to save the status of the Controller to the USB memory.
(1)
Insert the USB memory into the Controller.
(2)
In the [Main Menu] screen, move the cursor to [Controller States...], and press the <OK>
key. The following screen appears.
(3)
Select a folder to save the data.
The root directory is selected by default.
(4)
Press the <OK> key to save the status.
5.3.3 Load Data with EPSON RC+ 6.0
The following shows the procedure to read the data stored in the USB memory by EPSON
RC+ 6.0 and display the Controller status.
(1)
Insert the USB memory into the PC with EPSON RC+ 6.0.
(2)
Make use that the following folder is indicated in the USB memory.
S_ serial number_data status was saved
→
Exmaple: S_12345_200608074410
(3)
Copy the folder confirmed in procedure (2) to the “\EpsonRC60\Status” folder.
(4)
Select the EPSON RC+ 6.0 menu | Tools | Controller to display the [Controller Tools]
dialog.
(5)
Click the <Export Controller Status…> button.
Содержание RC620 CU
Страница 1: ...Rev 8 EM15XC3076F ROBOT CONTROLLER RC620 ...
Страница 2: ...ROBOT CONTROLLER RC620 Rev 8 ...
Страница 17: ...Safety This section contains information for safety of the Robot System ...
Страница 18: ......
Страница 23: ...Setup Operation This section contains information for setup and operation of the Robot Controller ...
Страница 24: ...8 RC620 Rev 8 ...
Страница 137: ...Maintenance This section contains maintenance procedures for the Robot Controller ...
Страница 138: ......