6.2 IP Address
Set the proper IP address or subnet mask depending on the Controller configuration to use
the LAN port.
Use an address from the following Private Address List in the closed network environment
such as P2P or production line. Also, make sure the address is not redundantly assigned
inside the closed network.
In other cases, check with the network administrator.
Configuration of the controller at shipment:
LAN-1 port
IP Address
: 192.168.0.1
IP Mask
: 255.255.255.0
IP Gateway
: 0.0.0.0
* LAN-1 port cannot automatically acquire the IP address (not support DHCP).
LAN-2 port
This port can acquire the IP address automatically.
6.3 Changing IP Address
6.3.1 LAN-1 port
Change the IP address of LAN-1 port.
(1)
Select the EPSON RC+ 6.0 menu | Setup | Controller to display the [Setup Controller]
dialog.
(2)
Enter the proper IP address and subnet mask and click the <Apply> button.
(3)
Click the <Close> button. The Controller reboots automatically.
IP address configuration is completed and the Controller reboot dialog disappears.
(4)
Connect the Ethernet cable to the Controller LAN-1 port.
LAN-1 port cannot automatically acquire the IP address (not support DHCP).
Private Address List
10.0.0.1
to
10.255.255.254
172.16.0.1
to
172.31.255.254
192.168.0.1
to
192.168.255.254
NOTE
Содержание RC620 CU
Страница 1: ...Rev 8 EM15XC3076F ROBOT CONTROLLER RC620 ...
Страница 2: ...ROBOT CONTROLLER RC620 Rev 8 ...
Страница 17: ...Safety This section contains information for safety of the Robot System ...
Страница 18: ......
Страница 23: ...Setup Operation This section contains information for setup and operation of the Robot Controller ...
Страница 24: ...8 RC620 Rev 8 ...
Страница 137: ...Maintenance This section contains maintenance procedures for the Robot Controller ...
Страница 138: ......