Setup & Operation 12. Option Slots
70
RC620 Rev.8
12.4.4 RS-232C Software Communication Setup (RS-232C)
Available communication settings are as follows.
Item
Specification
Baud Rates
110, 300, 600, 1200, 2400, 4800, 9600,
14400, 19200, 38400, 57600, 115200
Data bit length
7, 8
Stop bit length
1, 2
Parity
Odd, even, NA
Terminator
CR, LF, CRLF
Refer to
EPSON RC+ 6.0 Online Help
or
11. RS-232C Communications
for RS-232C
communication from the Robot application.
12.4.5 Communication Cable (RS-232C)
Prepare a communication cable as described in this section.
Connector
Standard
RS-232C
Connector
(Controller side)
D-sub 9 male pin
Mounting style #4 - 40
Use twisted pair cable for shielded wire.
Clamp the shield to the hood for noise prevention.
Pin assign of the RS-232C connector is as follows.
Pin No
Signal
Function
Signal Direction
1
DCD
Data carrier detect
Input
2
RXD
Receive data
Input
3
TXD
Send data
Output
4
DTR
Terminal ready
Output
5
GND
Signal ground
-
6
DSR
Data set ready
Input
7
RTS
Request to send
Output
8
CTS
Clear to send
Input
9
RI
Ring indicator
Input
12.5 PG Board
The PG board is used in the following 2 methods. For the details, refer to the each
manual.
- When used as the conveyor encoder
Refer to the
EPSON RC+ 6.0 Users Guide 15. Conveyor Tracking
.
- When used as the PG motion system
Refer to the
RC620 Robot Controller option PG Motion System manual
.
NOTE
Содержание RC620 CU
Страница 1: ...Rev 8 EM15XC3076F ROBOT CONTROLLER RC620 ...
Страница 2: ...ROBOT CONTROLLER RC620 Rev 8 ...
Страница 17: ...Safety This section contains information for safety of the Robot System ...
Страница 18: ......
Страница 23: ...Setup Operation This section contains information for setup and operation of the Robot Controller ...
Страница 24: ...8 RC620 Rev 8 ...
Страница 137: ...Maintenance This section contains maintenance procedures for the Robot Controller ...
Страница 138: ......