Setup & Operation 14. Option : Teach Pendant TP1
116
RC620 Rev.8
14.6 Troubleshooting
If the condition does not change after performing the countermeasure above, the unit may
have suffered a breakdown.
Please contact the service center or the manufacturer.
Display panel is blank
- The Controller supplies DC24V.
Check that the Controller RC620 is ON.
- Check that the Controller RC620 is connected to the TP port of the Controller properly.
An Error code appears and the Robot does not operate normally
- Please refer to the error code indicated in the following manual.
EPSON RC+6.0 SPEL+ Language reference
Robot does not move by pressing the Jog key
- Execute the Motor On command to energize the Robot motor.
(Refer to Motor On in the SPEL+ Language Reference)
- Energize the Robot motor.
(Refer to SLock in the SPEL+ Language Reference)
- Short jog distance may be selected.
Check the value in the [Jog Distance] screen and change the setting to long distance if
needed.
(Refer to
Setup & Operation 14.3.6 Jog Distance
)
Operation mode does not switch from TEACH mode to AUTO mode
- Send the latch release input signal to release the latch status.
Содержание RC620 CU
Страница 1: ...Rev 8 EM15XC3076F ROBOT CONTROLLER RC620 ...
Страница 2: ...ROBOT CONTROLLER RC620 Rev 8 ...
Страница 17: ...Safety This section contains information for safety of the Robot System ...
Страница 18: ......
Страница 23: ...Setup Operation This section contains information for setup and operation of the Robot Controller ...
Страница 24: ...8 RC620 Rev 8 ...
Страница 137: ...Maintenance This section contains maintenance procedures for the Robot Controller ...
Страница 138: ......