Maintenance 6. Maintenance Parts Replacement Procedures
RC620 Rev.8
167
6.4.1.2 BIOS Backup Battery (Normal)
CAUTION
Lithium batteries contain flammable materials such as lithium, organic
solvents, etc. If misused, batteries may generate heat, explode or catch
fire. Observe the following precautions for safe use of lithium batteries.
-
Be sure to use the battery supplied as the maintenance parts from
EPSON.
-
Do not allow the positive (+) and negative (-) electrodes to short circuit
during maintenance.
-
Do not discard batteries into fire or heat them to high temperature.
-
Do not disassemble or alter batteries.
-
Discarding batteries according to the regulations.
BIOS
Backup Battery
(Normal)
Removal
(1) Remove the CPU board.
Refer to
Maintenance: 6.4.1.1 CPU Board (Normal)
.
(2) Remove the BIOS backup battery placed behind the CPU board.
Front
Back
Remove the BIOS backup battery while pressing the latch of battery holder in the
direction shown in the photo.
Latch
Battery holder
1. Press
2. Remove
NOTE