Maintenance 6. Maintenance Parts Replacement Procedures
RC620 Rev.8
161
6.3.3 Replacing the Motor Driver (ADMB side)
Motor Driver
(ADMB side)
Removal
(1) Turn OFF the Controller power and disconnect the power plug.
(2) Remove 10 screws for the top panel
and remove the front panel.
(3) Remove a screw of the CPU fixing
plate and remove the CPU fixing plate.
(4) If the DVD drive is mounted, remove
the cables No. (25), (12)-4.
Refer to
Maintenance:
3.2
Diagram of Cable Connections
.
(5) Remove 4 screws for the DVD drive
fixing plate and remove the DVD
drive fixing plate.
(6) Remove 5 set screws of the side panel (Right side).