Maintenance 6. Maintenance Parts Replacement Procedures
RC620 Rev.8
149
6.1.3 Replacing the Small Fan
Small Fan
Removal
(1) Turn OFF the Controller.
(2) Remove the Large Fan.
Refer to
Maintenance: 6.1.2 Replacing the Large Fan
.
(3) Remove the UPS Battery.
Refer to
Maintenance: 6.2.2 Replacing the UPS Battery
.
(4) Remove 2 screws securing the Small
Fan and fan cover (Small).
Remove the fan cover (Small).
(5) Pull out the cable connector of Small
Fan from the DMB board to the
direction shown in the photo.
(6) Remove the Small Fan from the
Controller and pull out the fan cable to
the direction shown in the photo.
Be sure to pull the Small Fan slowly
and avoid the other cables to prevent
the fan connector from being trapped.
NOTE