Maintenance 6. Maintenance Parts Replacement Procedures
150
RC620 Rev.8
Small Fan
Installation
(1) Pass the cable of Small Fan through the
way shown in the photo.
Avoid the peripheral cables because the
fan connector can be caught in the
cables.
Path of Small Fan cable
(2) Connect the connector of Small Fan to
the DMB.
(3) Insert the Small Fan into the chassis in
the direction shown in the photo.
Be careful not to catch the cable
between the chassis and fan.
(4) Attach the fan cover (Small) to the Small Fan and secure them using 2 screws.
(5) Mount the UPS battery.
Refer to Maintenance:
6.2.2 Replacing the UPS Battery
.
(6) Mount the Large Fan.
Refer to
Maintenance: 6.1.2 Replacing the Large Fan
.
(7) Secure the front panel using 6 screws.
(8) If you removed the cables from TP port and USB port, connect them again.
(9) Plug in the power connector. Turn ON the Controller and make sure that the
Controller starts properly without any vibration or abnormal noise.
NOTE