- 210 -
SUMMARY OF SERIAL COMMANDS
E – EXECUTION COMMAND
Q – QUERY COMMAND (XX?)
S – SET UP COMMAND (XX=)
NOTE: IF AXIS I.D. IS NOT ZERO THEN ALL COMMANDS MUST BE PRECEDED
WITH AN AXIS IDENTIFIER (WHICH MAY BE 0 TO ADDRESS ALL DRIVES IN
CHAIN). IF AXIS I.D. IS ZERO THEN NO AXIS IDENTIFIER MAY BE USED (SINGLE
AXIS).
CMD EQS DESCRIPTION
AF
QS
AUTO FAULT REPORT ON(1)/OFF(0)
AL
QS
USER PROGRAMMABLE ACCEL LIMIT
AP
QS
AUTO END OF INDEX COUNT REPORT ON(1)/OFF(0)
ARX
QS
ANALOG CHANNEL RESPONSE (HEX) (0-7)
ATX
QS
ACCEL RAMP (MS TO MAX RPM)
AV
QS
ANALOG COMMAND CHANNEL VELOCITY FULL SCALE
(HEX)
BK
QS
ACTIVATE BRAKE(1)/DEACTIVATE BRAKE(0) OVERRIDE
BR
QS
INHIBIT BRIDGE(1)/ENABLE BRIDGE(0)
CC
Q
CURRENT COUNT
CD
Q
CURRENT DWELL
CFX
QS
ANALOG CHANNEL FULL SCALE (HEX)
CG
QS
CURRENT GAIN (HEX)
NOTE: A MODIFIER (0,1,2) MAY BE PRESENT WITH THE NV,EG,VG,DG,LG,CG
COMMANDS. IF NO MODIFIER IS PRESENT THE CURRENT SETTING IS SELECTED.
EXAMPLE:
VG1? (QUERY ONLY)
0 – MINIMUM VALUE FOR DRIVE MODEL
1 – MAXIMUM VALUE FOR DRIVE MODEL
2 – DEFAULT VALUE FOR DRIVE MODEL
CMD EQS DESCRIPTION
CHX
Q
ANALOG CHANNEL READING (0-5) (HEX)
CI
Q
CURRENT INDEX
CKX
Q
CHECKSUMS
CL
E
SERIAL CONTROL MODE CLEAR OF SUSPEND
CM
QS
CALIBRATE MODE
CM = 0
NORMAL OPERATING MODE
CM = 1
CALIBRATE MODE
CNX
QS
ANALOG CHANNEL NULL (HEX)
COX
QS
INDEX COUNT (0-65534) (65535 OR> = COUNT INFINITY)
CP
Q
COMMANDED POSITION (USER STEPS)
CTX
E
EXECUTE CALIBRATION TEST
CT1
SET NULL VELOCITY
CT2
SET VELOCITY GAIN (TACH SCALE FACTOR)
CAUTION: CT2, CAUSES THE MOTOR TO RUN AND THERE MUST BE FREE TRAVEL.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com