![Emerson EMC DX-202 Скачать руководство пользователя страница 137](http://html1.mh-extra.com/html/emerson-emc/dx-202/dx-202_manual_2400893137.webp)
- 136 -
T-16 SETUP AND OPERATION
The T-16 data entry screen is located in the parallel options in the PCX Setup Menu. Upon
selection of the Numeric Display option, the following screen will be displayed.
Figure 49
Screen Menu T-16 Numeric Display
NUMERIC DISPLAY INTERFACE
In order for the numeric display to function it must be enabled. Neither the thumbwheels or the
numeric displays can be used if the parallel interface is enabled.
DISPLAY FUNCTION
The numeric display may be setup to display any of the following positioning drive functions:
command position
command velocity
index count
index dwell time
motor current
DISPLAY DECIMAL POINT LOCATION
The user may place a decimal point at a fixed location on the numeric display. This option can
be used to make the display show meaningful information.