- 175 -
FUNCTION #
DESCRIPTION
29
PROGRAM INITIATE
Executes the selected program.
30
PROGRAM SELECT LINES
Sets the starting input line number for a given number of program select lines. Then the
number of program select lines is programmed through PCX or serial commands.
31
SUSPEND PROGRAM
Stops the execution of a program until the input line assigned with RESUME is activated.
Also see I/O Suspend Resume Feature Section in the PCM-1 Section.
32
RESUME PROGRAM
Resumes the execution of a suspended program.
Also see I/O Suspend Resume Feature Section in the PCM-1 Section.
33
CLEAR SUSPEND
Clears the IN SUSPEND output and returns the drive from a suspend cycle to normal
operation without the need to “RESUME” and completion of the suspended program.
Also see I/O Suspend Resume Feature Section in the PCM-1 Section.
34
CLEAR END OF PROGRAM OUTPUT
Clears the END OR PROGRAM output. If not assigned, the END OF PROGRAM output
will automatically clear when further motion is initiated.
35
CLEAR END OF PROGRAM COUNT
Clears the END OF PROGRAM output. If not assigned, the END OF PROGRAM output
will automatically clear when the next motion occurs.
38
BI-POLAR SYNC
An active input allows for BI-POLAR ratioing of the sync encoder to the drive motor.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com